ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 72:DPMU |
3 | Board No. | Number of the fault board Value range:0-8:DPMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255: None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 3:BTS30; 5:BTS312; 10:BTS3012A; 11:BTS3006A; 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Services may be interrupted when the TRX starts high temperature protection if the internal temperature of the cabinet is too high.
Run the LST BTSEXD command on the MML client.
Check whether the Upper Temperature Thrsh. and the Lower Temperature Thrsh. are below the threshold.
Y=> Go to Step 2.
N=> Huawei Customer Service Center.
Check the air conditioner and the fan. Clear the faults if any. View whether the alarm is cleared after the internal temperature of the cabinet resumes normal.
Y=> The alarm handling ends.
N=> Go to Step 3.
Check whether the threshold is below normal value. Note that the normal temperature inside the cabinet is 0°C°04-C.
Y=>Modify the threshold value.
The operation procedure is as follows:
Run the SET BTSEXD command on the MML client.
Modify the Upper Temperature Thrsh. and Check if the alarm is cleared.The alarm is cleared. Alarm handling is completed. The alarm is not cleared. Go to Step 4.
N=>The threshold is normally set. Go to step 4.
Check the temperature sensor. Replace the temperature sensor if faulty. View whether the alarm is cleared.
Y=> The alarm handling ends.