ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 72:DPMU |
3 | Board No. | Number of the fault board Value range:0-8:DPMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255: None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 3:BTS30; 5:BTS312; 10:BTS3012A; 11:BTS3006A; 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
The operation procedure is as follows:
Run the LST BTSEXD command on the MML client .
The Lower Humidity Threshold can be viewed.
Y=>Go to Step 2.
N=>The humidity is normal. Go to step 4.
See if the alarm is cleared.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The alarm is not cleared. Go to step 4.
Check whether the lower humidity threshold is set higher than normal. Note that the normal humidity for the BTS is from15%RH to 85%RH.
Y=>Modify the lower humidity threshold and check if the alarm is cleared.
N=>Go to step 4.
See if the alarm is cleared.
Y=>The alarm is cleared. Alarm handling is completed.
N=>The alarm is not cleared. Please contact Huawei Customer Service Center.