ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 72:DPMU |
3 | Board No. | Number of the fault board Value range:0-8:DPMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255: None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
The PMU monitors the AC voltage. This alarm will be generated when the voltage is below the lower limit ( default value :180V).
Y => The AC power supply network and the cable connection in the equipment room are faulty. Perform onsite checks, and contact the power supply departments and property departments to troubleshoot the faults on the power supply network. If the input AC power is normal but the alarm persists, contact Huawei Customer Service Center.
N => If the current voltage of the AC power is basically within the operating range and the alarm is cleared automatically, you can infer that the power supply is instable. For example, the power supply is interrupted, or overvoltage or undervoltage occurs. Otherwise, contact Huawei Customer Service Center.