ALM-6052 Boolean 4 Alarm

Description

This alarm is generated when the extended Boolean 4 is abnormal.

Attribute

Alarm ID Alarm Severity Alarm Type
6052 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

72:APM

3 Board No.

Number of the fault board

Value range:0-8:APMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

This external alarm of the power system is generated when the status of the extended Boolean changes. The extended Boolean is configured by the users.

Procedure

  1. a) Check whether the Boolean alarm needs to be configured.

    Y => Go to step 2.

    N => Go to step b.

    b) Disable the Boolean alarm. After the Boolean alarm is disabled, check whether the alarm is cleared.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.

  2. a) Check whether the output connection of the sensor is changed.

    Y => Go to step b.

    N => Go to step 3.

    b) Handle it according to the settings of the Boolean alarm. Check whether the alarm is cleared

    Y => The alarm is cleared. No further action is required.

    N => Go to step 3.

  3. a) Check whether the sensor is faulty or the cable is incorrectly connected.

    Y => Go to step b.

    N => Go to step 4.

    b) Replace the sensor or reconnect the cable of the sensor. Check whether the alarm is cleared.

    Y => The alarm is cleared. No further action is required.

    N => Go to step 4.

  4. Replace the APMU and then check whether the alarm is cleared.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.