ALM-6054 Boolean 5 Alarm

Description

This alarm is generated when the extended Boolean 5 is abnormal.

Attribute

Alarm ID Alarm Severity Alarm Type
6054 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

72:APM

3 Board No.

Number of the fault board

Value range:0-8:APMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

This external alarm of the power system is generated when the status of the extended Boolean changes. The extended Boolean is configured by the users.

Procedure

  1. Check whether the Boolean alarm needs to be configured.
    1. Check whether the Boolean alarm needs to be configured.

      Y=> Go to step 2.

      N=> Go to b.

    2. Disable the Boolean alarm. Disable the Boolean alarm to see if the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> The alarm is not cleared. Please contact Huawei Customer Service Center.

  2. Check whether the sensor output contact changes.
    1. Check whether the sensor output contact changes.

      Y=> Go to b.

      N=> Go to step 3.

    2. Handle it according to the settings of the Boolean alarm. See if the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to step 3.

  3. Check whether the sensor or the connection line is faulty.
    1. Check whether the sensor or the connection line is faulty.

      Y=> Go to b].

      N=> Go to step 4.

    2. Replace the sensor or reconnect the line of the sensor. See if the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to step 4.

  4. Replace the APMU. See if the alarm is cleared.

    Y=>The alarm is cleared. The alarm handling is complete.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.