ALM-6066 Extended Boolean 5 Alarm

Description

This alarm is reported when the extended Boolean 5 is abnormal.

Attribute

Alarm ID Alarm Severity Alarm Type
6066 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

133:APM/APMU

3 Board No.

Number of the fault board

Value range:0-8:APMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255: None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

This alarm is one type of APM external alarm. The state of the Boolean values that corresponding to the APM is configured by the user.

Procedure

  1. Check if the Boolean alarm needs to be configured.
    1. Check if the Boolean alarm needs to be configured.

      Y=>Go to Step 2.

      N=>Go to Step b.

    2. Disable the Boolean alarm and see if the alarm is cleared.

      Y=>Alarm handling is completed.

      N=>The alarm is not cleared. Please contact Huawei Customer Service Center.

  2. Check if the output contact of the sensor is changed.
    1. Check if the output contact of the sensor is changed.

      Y=>Go to Step b.

      N=>Go to Step 3.

    2. Handle the Boolean value alarm according to the actual configuration and see if the alarm is cleared.

      Y=>Alarm handling is completed.

      N=>The alarm is not cleared. Go to Step 3.

  3. Check if the sensor and its connecting cables are faulty.
    1. Check on site if the sensor and its connecting cables are faulty.

      Y=>Go to Step b.

      N=>Go to Step 4.

    2. Replace the faulty sensor or re-connect its connecting cables and see if the alarm is cleared.

      Y=>Alarm handling is completed.

      N=>The alarm is not cleared. Go to Step 4.

  4. Replace the APMU and see if the alarm is cleared.

    Y=>Alarm handling is completed.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential