ALM-6488 -48V Power too Low Alarm

Description

The alarm is reported when the voltage of the -48V power supply is lower than the lower threshold (default: -42V).

Attribute

Alarm ID Alarm Severity Alarm Type
6488 Minor Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

0-2:DEMU/EMU

3 Board No.

Number of the fault board

0-2:DEMU/EMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services may be interrupted.

System Actions

None.

Possible Causes

  • The alarm threshold is wrong.
  • Alarm occurs in the power supply equipment.
  • The environment monitoring module is faulty.

Procedure

  1. Check for the abnormal output of the power cabinet.
    1. Check the power cabinet, and rectify the fault if any.
    2. Check whether the alarm is cleared:

      Y => The alarm is cleared. The alarm handling ends.

      N => The alarm is not cleared. Go to procedure 2.

  2. Check the threshold of the abnormal voltage alarm.
    1. Check the threshold setting of the abnormal voltage alarm of the –48 V power:

      Y => Contact Huawei.

      N => Go to step b.

    2. Set the threshold of the –48 V power alarm.
    3. Check whether the alarm is cleared:

      Y => The alarm is cleared. The alarm handling ends.

      N => The alarm is not cleared. Contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.