65489 BTS Custom Environment Alarm106

Description

The alarm is reported by envionment monitor

Attribute

Alarm ID Alarm Severity Alarm Type
65489 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board is located.

2 Board Type

Number of the type which the faulty board belongs to.

3 Board No.

Number of the fault board

4 The number of passage

Number of the passage where the faulty board is located.

5 SubLink No.

Number of the alarm sublink.

6 Cell Index

Number of the cell where the faulty board is located.

7 Site Type.

0=BTS22C,2=BTS20,3=BTS30,5=BTS312,7=BTS3001C-108 or BTS3001C-116,8=BTS3001C-204,9=BTS3002C,10=BTS3012A,11=BTS3006A,12=BTS3012,13=BTS3006C,14=BTS3002E,15=BTS3012AE,16=BTS3012 II,17=DBS3900 GSM,18=BTS3900 GSM,19=BTS3900A GSM,20=BTSDBS3036,21=BTS3036,22=BTS3036A,29=BTS3900B,30=BTS3900E

8 Number of subrack

Number of the rack where the faulty board is located.

9 The number of the cabinet

Number of the subrack where the faulty board is located.

10 The number of slot

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

0=Normal,1=Transient Count

13 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

A potential risk for the normal operation of the system exists.

System Actions

The alarm persists or can be cleared by comparing the detection value (factory value) of the digital sensor with the actual environment.

Possible Causes

The digital sensor that is connected to the BSC is triggered.

Procedure

  1. Check whether the BSC or the equipment room is in good condition. If no, solve the relevant problems. Check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm persists. Please Contact Huawei Customer Service Center .