ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Number of the subrack of the IP-based interface board |
2 | Slot No. | Number of the slot of the IP-based interface board |
3 | Port No. | Number of the port of the IP-based interface board |
4 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
Working mode of FE port isn't 100M&full duplex,or working mode of GE port isn't 1000M&full duplex.
Y=> Go to 2.
N=> Modify the configuration of the interface board over IP.
Y=> Go to 3.
N=> Contact the maintenance engineers of the peer equipment. The alarm handling is complete.
Y=> Request the maintenance engineers of transmission network to replace the half-duplex Ethernet hub with a full-duplex Ethernet switch. The alarm handling is complete.