802 Error of Transaction Logging File

Description

When the system is restarted, the alarm is reported if faults occur on the transaction log.

Attribute

Alarm ID Alarm Severity Alarm Type
802 Critical Event

Parameters

ID Name Meaning
1 The cause

1=The transaction logging file was not consistent with the baseline,2=There was invalid transaction logging,3=The Transaction logging file did not exist

2 Alarm Attribute

0=Normal, Alarms period are longer than the Transient Threshold.

1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN".

Impact on the System

The data used for restoration is invalid.

System Actions

None.

Possible Causes

  • (1)The transaction logging file was not consistent with the baseline.
  • (2) There was invalid transaction logging.
  • (3)The Transaction logging file did not exist.

Procedure

  1. None.