ALM-8580 Heat Exchanger Fault Alarm

Description

This alarm is reported when the temperature of the driving board of the heat exchanger is abnormal, or the outer circulation fan is faulty.

Attribute

Alarm ID Alarm Severity Alarm Type
8580 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

140:OSSU

3 Board No.

Number of the fault board

0:OSSU0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

  • If the heat exchanger stops working completely, the temperature inside the cabinet will rise until the over temperature protection of the cabinet is triggered. The services will be interrupted.
  • Note:
  • The heat exchanger can work in either DC or AC power supply. Therefore, it only stops working completely when both DC and AC power supply fail.

System Actions

None.

Possible Causes

  • The temperature of the driving board of the heat exchanger is higher than 68 oc or lower than -4 oc.
  • The outer circulation fan is faulty (The running speed is less than 600 rotation/second).

Procedure

  1. Check if there is a heat exchanger temperature alarm.

    Y=>Go to Step 2.

    N=>Go to Step 5.

  2. Check the temperature of other modules in the cabinet to see if it is too high or too low.

    Y=>Go to Step 3.

    N=>Please contact Huawei Customer Service Center.

  3. Check if the heat exchanger is faulty.

    Y=>Go to Step 4.

    N=>The heat exchanger is normal,Please contact Huawei Customer Service Center.

  4. Replace the heat exchanger.

  5. Check if the outer circulation fan is faulty.

    Y=>Go to Step 6.

    N=>Please contact Huawei Customer Service Center.

  6. Replace the outer circulation fan and see if the alarm is cleared.

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared,Please contact Huawei Customer Service Center.