ALM-9698 Board Type Mismatch Alarm

Description

This alarm is triggered when the system detects that the actual board type is inconsistent with the data configuration at the BSC side or the frequency band inconsistent with the TRX frequency.

Attribute

Alarm ID Alarm Severity Alarm Type
9698 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

147:PBU

3 Board No.

Number of the fault board

0:PBU 0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:The slot is installed with the TRX, while the configuration at the BSC side is PBU.

1:The PBU frequency band is inconsistent with the corresponding TRX frequency.

2:The slot is installed with the P-PBU, while the configuration at the BSC side is different.

3:The slot is installed with the R-PBU, while the configuration at the BSC side is different.

4:The slot is installed with the D-PBU, while the configuration at the BSC side is different.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When the alarm occurs, all the services supported by the TRX will be interrupted.

System Actions

None.

Possible Causes

  • The actual board type is inconsistent with data configuration.
  • The actual board frequency band is inconsistent with data configuration.

Procedure

  1. Check data configuration

    Check the board type by adhering, do as follows:

    Right-click the PBU and choose Query Board Information on the shortcut menu.

  2. Check the board type in the corresponding slot.

    The board type can be viewed under the corresponding rack from the right pane

  3. Unify the board type in the data configuration with the board installed.

    The following methods can be applied:

    Replace the board according to the configuration at the BSC Data Auto Configuration System.

    Reconfigured the board type under the Site Device to match with the board installed.

  4. Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Please contact Huawei Customer Service Center.