ALM-9750 Damp alarm

Description

The humidity values are invalid for successive 60 seconds and the alarms are reported; Or, the humidity is higher than the over humidity threshold for successive 60 seconds; or the humidity is lower than the under threshold for successive 60 seconds;

Attribute

Alarm ID Alarm Severity Alarm Type
9750 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

93:FMU

94:FMUA

3 Board No.

Number of the fault board

0-7:FMU/FMUA

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:over alarm

1:under alarm

2:sensor invalid alarm

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

  • The temperature sensor on the fan board is faulty.
  • The fan board is faulty.
  • The alarm threshold is set improperly.
  • The humidity of the environment is not normal.

System Actions

None.

Possible Causes

  • The temperature sensor on the fan board is faulty.
  • The fan board is faulty.
  • The alarm threshold is set improperly.
  • The humidity of the environment is not normal.

Procedure

  1. Check whether this is a sensor invalid alarm based on the alarm tributary number. If so, go to a; if no, check whether this is an overtemperature alarm. If so, go to b; if no, go to c.
    1. humidity sensor invalid alarm.
    2. Check whether the humidity value is proper.

      Y=> Go to Step 7.

      N=> Go to Step 2.

    3. Check whether the humidity sensor is connected properly.

      Y=> Go to Step 4.

      N=> Go to Step 3.

    4. Connect the humidity sensor properly.
    5. Check whether the cable is connected properly.

      Y=> Go to Step 6.

      N=> Go to Step 5.

    6. Replace the cable.
    7. Replace the environment sensor and check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to Step 7.

    8. Reset the fan control board and check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to Step 8.

    9. Replace the fan control board.
    10. Ambient Humidity Too High
    11. Check whether the humidity value is proper.

      Y=> Go to Step 3.

      N=> Go to Step 2.

    12. Check whether the humidity value and the actual value are consistent.

      N=> Go to Step 4.

    13. Reset the fan control board and check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to Step 4.

    14. Replace the humidity sensor and check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to Step 5.

    15. Replace the fan control board.
    16. Ambient Humidity Too Low
    17. Check whether the humidity value is lower than the alarm threshold.

      Y=> Go to Step 3.

      N=> Go to Step 7.

    18. Check whether the humidity value and the actual value are consistent.

      N=> Go to Step 4.

    19. Reset the fan control board +CQ22 and check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to Step 4.

    20. Replace the humidity sensor and check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> Go to Step 5.

    21. Replace the fan control board.

Huawei Proprietary and Confidential