ALM-9752 Smog alarm

Description

The smoke voltage and the alarm voltage are consistent for 20 seconds.

Attribute

Alarm ID Alarm Severity Alarm Type
9752 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

93:FMU

94:FMUA

3 Board No.

Number of the fault board

0-7:FMU/FMUA

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

  • The sensor is damaged.
  • The alarm voltage is incorrect.
  • The board is faulty.
  • The sensor cable is faulty.
  • There is too much smoke.

System Actions

None.

Possible Causes

  • The sensor is damaged.
  • The alarm voltage is incorrect.
  • The board is faulty.
  • The sensor cable is faulty.
  • There is too much smoke.

Procedure

  1. Check whether there is fire in the field.

    Y=> There is a fire. Go to step 2.

    N=> There is no fire. Go to Step step 3 .

  2. . Extinguish the fire in the equipment room.

    After the fire in the equipment room is extinguished, check whether the alarm is cleared.

    Y=> the alarm handling is complete.

    N=> The alarm is not cleared. Go to step 3.

  3. . Check other fault causes.
    1. Issue the alarm reset the command.

      Issue the alarm reset command through the maintenance console and check whether the alarm is cleared.

      Y=> the alarm handling is complete.

      N=> The alarm is not cleared. Go to b.

    2. Check whether the smoke sensor is normal. Replace the sensor if necessary. Check whether the alarm is cleared.

      Y=> the alarm handling is complete.

      N=> The alarm is not cleared. Go to c.

    3. Ensure that the sensor wire is securely connected. Check whether the alarm is cleared.

      Y=> The alarm is cleared. The alarm handling is complete.

      N=> The alarm is not cleared. Go to d.

    4. Reset the board by means of software and hardware. Check whether the alarm is cleared.

      Y=> the alarm handling is complete.

      N=> Please contact Huawei Customer Service Center.