ALM-9768 nfcb not consistant with physical alarm

Description

The configured fan type is inconsistent with the actual fan type.

Attribute

Alarm ID Alarm Severity Alarm Type
9768 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

93:FMU

94:FMUA

3 Board No.

Number of the fault board

0-8:FMU/FMUA

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number 0: First FAN board in slot 8; 1: Second FAN board in slot 9; 2: Third FAN board in slot 10; 3: Fourth FAN board in slot 11.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

If the FMU is configured for the FMUA installed in the outdoor cabinet, some functions cannot be performed.

System Actions

None.

Possible Causes

The configuration of the fan type is faulty.

Procedure

  1. If the FMU is configured and the alarm is reported, change the fan type to FMUA;

  2. If the FMUA is configured and the alarm is reported, change the fan type to FMU.