DIP Switches on the boards

This describes the DIP switches on the boards.

DMCM

The DIP switches on the DMCM specify the grounding of eight E1 routes.Table 1lists their detailed settings.

Table 1 Description of the DIP switches on the DMCM

DIP Switch

DIP Bit

ON/OFF

Function

E1-R0/1

1

ON

The ring of the transmitting end of E1 0 is grounded.

OFF

The ring of the transmitting end of E1 0 is not grounded.

2

ON

The ring of the receiving end of E1 0 is grounded.

OFF

The ring of the receiving end of E1 0 is not grounded.

3

ON

The ring of the transmitting end of E1 1 is grounded.

OFF

The ring of the transmitting end of E1 1 is not grounded.

4

ON

The ring of the receiving end of E1 1 is grounded.

OFF

The ring of the receiving end of E1 1 is not grounded.

E1-R2/3

1

ON

The ring of the transmitting end of E1 2 is grounded.

OFF

The ring of the transmitting end of E1 2 is not grounded.

2

ON

The ring of the receiving end of E1 2 is grounded.

OFF

The ring of the receiving end of E1 2 is not grounded.

3

ON

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the ring of the third TX E1 route is grounded.
  • For the DMCM (Abis Bypass), the status of OML1 is ON.

OFF

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the ring of the third TX E1 route is not grounded.
  • For the DMCM (Abis Bypass), the status of OML1 is OFF.

4

ON

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the ring of the third RX E1 route is grounded.
  • For the DMCM (Abis Bypass), the status of OML2 is ON.

OFF

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the ring of the third RX E1 route is not grounded.
  • For the DMCM (Abis Bypass), the status of OML2 is OFF.

75/120

1

ON

E1 0 matches 75-ohm resistance.

OFF

E1 0 matches 120-ohm resistance.

2

ON

E1 1 matches 75-ohm resistance.

OFF

E1 1 matches 120-ohm resistance.

3

ON

E1 2 matches 75-ohm resistance.

OFF

E1 2 matches 120-ohm resistance.

4

ON

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), indicates E1_3 matches 75-ohm resistance.
  • For the DMCM (Abis Bypass), the status of OML3 is ON.

OFF

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), indicates E1_3 matches 120-ohm resistance.
  • For the DMCM (Abis Bypass), the status of OML3 is OFF.

MODE

1

ON

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the transmission mode is E1 transmission.
  • For the DMCM (Abis Bypass), the bypass function in case of poweroff is enabled.

OFF

  • For the DMCM (With SDH Module), the transmission mode is optical transmission.
  • For the DMCM (Without SDH Module), the DIP switch cannot be set to this status.
  • For the DMCM (Abis Bypass), the bypass function in case of poweroff is disabled.

2

ON

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the DIP switch is reserved.
  • For the DMCM (Abis Bypass), the bypass function in case of poweroff is enabled.

OFF

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the DIP switch is reserved.
  • For the DMCM (Abis Bypass), the bypass function in case of poweroff is disabled.

3

ON

Formal software status

OFF

Aging software status

4

ON

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the DIP switch is reserved.
  • For the DMCM (Abis Bypass), the bypass function in case of poweroff is enabled.

OFF

  • For the DMCM (With SDH Module) and the DMCM (Without SDH Module), the DIP switch is reserved.
  • For the DMCM (Abis Bypass), the bypass function in case of poweroff is disabled.
CAUTION:

If you need to configure the DMCM (Abis Bypass) as bypass function enabled or bypass function disabled, Bits 1, 2, 4 of the MODE switch must be set to the same status.

Table 2 describes the OML DIP switches on the DMCM.

Table 2 Description of the OML DIP switches on the DMCM

Settings of the OML DIP Switch

E1 Timeslot

OML1

(E1-R2/3.3)

OML2

(E1-R2/3.4)

OML3

(75/120.4)

ON

ON

ON

31

OFF

ON

ON

30

ON

OFF

ON

29

OFF

OFF

ON

28

ON

ON

OFF

27

OFF

ON

OFF

3

ON

OFF

OFF

6

OFF

OFF

OFF

9

Table 3 describes the RACK DIP switches on the DMCM.

Table 3 Description of the RACK DIP Switches on the DMCM

Bits on the RACK DIP Switch

Function

4

3

2

1

ON

ON

ON

ON

Rack 0 indicates the main cabinet in the main cabinet group.

ON

ON

ON

OFF

Rack 1 indicates the extension cabinet in the main cabinet group.

ON

ON

OFF

ON

Rack 2 indicates the extension cabinet in the main cabinet group.

ON

ON

OFF

OFF

Rack 3 indicates the main cabinet in the extension cabinet group.

ON

OFF

ON

ON

Rack 4 indicates the extension cabinet in the extension cabinet group.

ON

OFF

ON

OFF

Rack 5 indicates the extension cabinet in the extension cabinet group.

NOTE:

Bit 4 on the RACK DIP switch is reserved temporarily. Bit 4 is ON by default.

DTMU

The DIP switches on the DTMU specify the grounding of eight E1 routes.Table 4lists their detailed settings.

Table 4 Settings of the DIP switches on the DTMU

DIP Switch

DIP Bit

ON/OFF

Description

S5

1

ON

Ring of the first TX E1 route is grounded.

OFF

Ring of the first TX E1 route is not grounded.

2

ON

Ring of the first RX E1 route is grounded.

OFF

Ring of the first RX E1 route is not grounded.

3

ON

Ring of the second TX E1 route is grounded.

OFF

Ring of the second TX E1 route is not grounded.

4

ON

Ring of the second RX E1 route is grounded.

OFF

Ring of the second RX E1 route is not grounded.

S4

1

ON

Ring of the third TX E1 route is grounded.

OFF

Ring of the third TX E1 route is not grounded.

2

ON

Ring of the third RX E1 route is grounded.

OFF

Ring of the third RX E1 route is not grounded.

3

ON

Ring of the fourth TX E1 route is grounded.

OFF

Ring of the fourth TX E1 route is not grounded.

4

ON

Ring of the fourth RX E1 route is grounded.

OFF

Ring of the fourth RX E1 route is not grounded.

S7

1

ON

Ring of the fifth TX E1 route is grounded.

OFF

Ring of the fifth TX E1 route is not grounded.

2

ON

Ring of the fifth RX E1 route is grounded.

OFF

Ring of the fifth RX E1 route is not grounded.

3

ON

Ring of the sixth TX E1 route is grounded.

OFF

Ring of the sixth TX E1 route is not grounded.

4

ON

Ring of the sixth RX E1 route is grounded.

OFF

Ring of the sixth RX E1 route is not grounded.

S6

1

ON

Ring of the seventh TX E1 route is grounded.

OFF

Ring of the seventh TX E1 route is not grounded.

2

ON

Ring of the seventh RX E1 route is grounded.

OFF

Ring of the seventh RX E1 route is not grounded.

3

ON

Ring of the eighth TX E1 route is grounded.

OFF

Ring of the eighth TX E1 route is not grounded.

4

ON

Ring of the eighth RX E1 route is grounded.

OFF

Ring of the eighth RX E1 route is not grounded.

NOTE:

Adhere to the following principles to set the DIP switches on the DTMU:

  • Set all the DIP switches to ON when the 75-ohm E1 cable is used for the BTS.
  • Set all the DIP switches to OFF when the 120-ohm E1 cable is used for the BTS.

GTMU&UELP

The GTMU has five DIP switches. Each DIP switch has four DIP bits. The DIP switches S1 and S2 should be set in pairs,the functions of the DIP switches are as follows:

Table 5 Settings of S1

DIP Switch

DIP Status

Description

1

2

S1

ON

ON

The E1 impedance is set to 75 ohms.

OFF

ON

The E1 impedance is set to 120 ohms.

ON

OFF

The T1 impedance is set to 100 ohms.

NOTE:

The DIP bits 3 and 4 of S1 should retain the default settings. The default settings are OFF. If they are ON, you should change them to OFF.

Table 6 Settings of S2

DIP Switch

DIP Status

Description

1

2

3

4

S2

OFF

OFF

OFF

OFF

All the DIP bits of S2 are set to OFF (balanced mode) by default in all modes.

ON

ON

ON

ON

When four 75-ohm E1 links are faulty, all the DIP bits of S2 should be set to ON (unbalanced mode) so that the faults are rectified.

Other settings of the DIP bits

Disabled

Table 7 Settings of S4

DIP Switch

DIP Status

Description

1

2

3

4

S4

ON

ON

ON

ON

The E1 link can be bypassed.

OFF

OFF

OFF

OFF

The E1 link cannot be bypassed.

Other settings of the DIP bits

Disabled

Table 8 Settings of S5

DIP Switch

DIP Status

Description

1

2

3

4

S5

ON

ON

ON

ON

The E1 link cannot be bypassed.

OFF

ON

ON

OFF

The E1 link of the Level 1 cascaded BTS can be bypassed.

ON

OFF

ON

OFF

The E1 link of the Level 2 cascaded BTS can be bypassed.

OFF

OFF

ON

OFF

The E1 link of the Level 3 cascaded BTS can be bypassed.

ON

ON

OFF

OFF

The E1 link of the Level 4 cascaded BTS can be bypassed.

OFF

ON

OFF

OFF

The E1 link of the Level 5 cascaded BTS can be bypassed.

NOTE:

The E1 bypass function is not supported at this version. All the DIP bits of S4 should be set to OFF, and all the DIP bits of S5 should be set to ON.

Table 9describes the DIP switch on the UELP.

Table 9 DIP switch on the UELP

DIP Switch

DIP Status

Description

1

2

3

4

S1

ON

ON

ON

ON

Used for the 75-ohm unbalanced mode

OFF

OFF

OFF

OFF

Used for other modes except the 75-ohm unbalanced mode


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.