This describes the DIP switches on the boards.
The DIP switches on the DMCM specify the grounding of eight E1 routes.Table 1lists their detailed settings.
DIP Switch |
DIP Bit |
ON/OFF |
Function |
---|---|---|---|
E1-R0/1 |
1 |
ON |
The ring of the transmitting end of E1 0 is grounded. |
OFF |
The ring of the transmitting end of E1 0 is not grounded. |
||
2 |
ON |
The ring of the receiving end of E1 0 is grounded. |
|
OFF |
The ring of the receiving end of E1 0 is not grounded. |
||
3 |
ON |
The ring of the transmitting end of E1 1 is grounded. |
|
OFF |
The ring of the transmitting end of E1 1 is not grounded. |
||
4 |
ON |
The ring of the receiving end of E1 1 is grounded. |
|
OFF |
The ring of the receiving end of E1 1 is not grounded. |
||
E1-R2/3 |
1 |
ON |
The ring of the transmitting end of E1 2 is grounded. |
OFF |
The ring of the transmitting end of E1 2 is not grounded. |
||
2 |
ON |
The ring of the receiving end of E1 2 is grounded. |
|
OFF |
The ring of the receiving end of E1 2 is not grounded. |
||
3 |
ON |
|
|
OFF |
|
||
4 |
ON |
|
|
OFF |
|
||
75/120 |
1 |
ON |
E1 0 matches 75-ohm resistance. |
OFF |
E1 0 matches 120-ohm resistance. |
||
2 |
ON |
E1 1 matches 75-ohm resistance. |
|
OFF |
E1 1 matches 120-ohm resistance. |
||
3 |
ON |
E1 2 matches 75-ohm resistance. |
|
OFF |
E1 2 matches 120-ohm resistance. |
||
4 |
ON |
|
|
OFF |
|
||
MODE |
1 |
ON |
|
OFF |
|
||
2 |
ON |
|
|
OFF |
|
||
3 |
ON |
Formal software status |
|
OFF |
Aging software status |
||
4 |
ON |
|
|
OFF |
|
If you need to configure the DMCM (Abis Bypass) as bypass function enabled or bypass function disabled, Bits 1, 2, 4 of the MODE switch must be set to the same status.
Table 2 describes the OML DIP switches on the DMCM.
Settings of the OML DIP Switch |
E1 Timeslot |
||
---|---|---|---|
OML1 (E1-R2/3.3) |
OML2 (E1-R2/3.4) |
OML3 (75/120.4) |
|
ON |
ON |
ON |
31 |
OFF |
ON |
ON |
30 |
ON |
OFF |
ON |
29 |
OFF |
OFF |
ON |
28 |
ON |
ON |
OFF |
27 |
OFF |
ON |
OFF |
3 |
ON |
OFF |
OFF |
6 |
OFF |
OFF |
OFF |
9 |
Table 3 describes the RACK DIP switches on the DMCM.
Bits on the RACK DIP Switch |
Function |
|||
---|---|---|---|---|
4 |
3 |
2 |
1 |
|
ON |
ON |
ON |
ON |
Rack 0 indicates the main cabinet in the main cabinet group. |
ON |
ON |
ON |
OFF |
Rack 1 indicates the extension cabinet in the main cabinet group. |
ON |
ON |
OFF |
ON |
Rack 2 indicates the extension cabinet in the main cabinet group. |
ON |
ON |
OFF |
OFF |
Rack 3 indicates the main cabinet in the extension cabinet group. |
ON |
OFF |
ON |
ON |
Rack 4 indicates the extension cabinet in the extension cabinet group. |
ON |
OFF |
ON |
OFF |
Rack 5 indicates the extension cabinet in the extension cabinet group. |
Bit 4 on the RACK DIP switch is reserved temporarily. Bit 4 is ON by default.
The DIP switches on the DTMU specify the grounding of eight E1 routes.Table 4lists their detailed settings.
DIP Switch |
DIP Bit |
ON/OFF |
Description |
---|---|---|---|
S5 |
1 |
ON |
Ring of the first TX E1 route is grounded. |
OFF |
Ring of the first TX E1 route is not grounded. |
||
2 |
ON |
Ring of the first RX E1 route is grounded. |
|
OFF |
Ring of the first RX E1 route is not grounded. |
||
3 |
ON |
Ring of the second TX E1 route is grounded. |
|
OFF |
Ring of the second TX E1 route is not grounded. |
||
4 |
ON |
Ring of the second RX E1 route is grounded. |
|
OFF |
Ring of the second RX E1 route is not grounded. |
||
S4 |
1 |
ON |
Ring of the third TX E1 route is grounded. |
OFF |
Ring of the third TX E1 route is not grounded. |
||
2 |
ON |
Ring of the third RX E1 route is grounded. |
|
OFF |
Ring of the third RX E1 route is not grounded. |
||
3 |
ON |
Ring of the fourth TX E1 route is grounded. |
|
OFF |
Ring of the fourth TX E1 route is not grounded. |
||
4 |
ON |
Ring of the fourth RX E1 route is grounded. |
|
OFF |
Ring of the fourth RX E1 route is not grounded. |
||
S7 |
1 |
ON |
Ring of the fifth TX E1 route is grounded. |
OFF |
Ring of the fifth TX E1 route is not grounded. |
||
2 |
ON |
Ring of the fifth RX E1 route is grounded. |
|
OFF |
Ring of the fifth RX E1 route is not grounded. |
||
3 |
ON |
Ring of the sixth TX E1 route is grounded. |
|
OFF |
Ring of the sixth TX E1 route is not grounded. |
||
4 |
ON |
Ring of the sixth RX E1 route is grounded. |
|
OFF |
Ring of the sixth RX E1 route is not grounded. |
||
S6 |
1 |
ON |
Ring of the seventh TX E1 route is grounded. |
OFF |
Ring of the seventh TX E1 route is not grounded. |
||
2 |
ON |
Ring of the seventh RX E1 route is grounded. |
|
OFF |
Ring of the seventh RX E1 route is not grounded. |
||
3 |
ON |
Ring of the eighth TX E1 route is grounded. |
|
OFF |
Ring of the eighth TX E1 route is not grounded. |
||
4 |
ON |
Ring of the eighth RX E1 route is grounded. |
|
OFF |
Ring of the eighth RX E1 route is not grounded. |
Adhere to the following principles to set the DIP switches on the DTMU:
The GTMU has five DIP switches. Each DIP switch has four DIP bits. The DIP switches S1 and S2 should be set in pairs,the functions of the DIP switches are as follows:
DIP Switch |
DIP Status |
Description | |
---|---|---|---|
1 |
2 |
||
S1 |
ON |
ON |
The E1 impedance is set to 75 ohms. |
OFF |
ON |
The E1 impedance is set to 120 ohms. |
|
ON |
OFF |
The T1 impedance is set to 100 ohms. |
The DIP bits 3 and 4 of S1 should retain the default settings. The default settings are OFF. If they are ON, you should change them to OFF.
DIP Switch |
DIP Status |
Description | |||
---|---|---|---|---|---|
1 |
2 |
3 |
4 |
||
S2 |
OFF |
OFF |
OFF |
OFF |
All the DIP bits of S2 are set to OFF (balanced mode) by default in all modes. |
ON |
ON |
ON |
ON |
When four 75-ohm E1 links are faulty, all the DIP bits of S2 should be set to ON (unbalanced mode) so that the faults are rectified. |
|
Other settings of the DIP bits |
Disabled |
DIP Switch |
DIP Status |
Description | |||
---|---|---|---|---|---|
1 |
2 |
3 |
4 |
||
S4 |
ON |
ON |
ON |
ON |
The E1 link can be bypassed. |
OFF |
OFF |
OFF |
OFF |
The E1 link cannot be bypassed. |
|
Other settings of the DIP bits |
Disabled |
DIP Switch |
DIP Status |
Description | |||
---|---|---|---|---|---|
1 |
2 |
3 |
4 |
||
S5 |
ON |
ON |
ON |
ON |
The E1 link cannot be bypassed. |
OFF |
ON |
ON |
OFF |
The E1 link of the Level 1 cascaded BTS can be bypassed. |
|
ON |
OFF |
ON |
OFF |
The E1 link of the Level 2 cascaded BTS can be bypassed. |
|
OFF |
OFF |
ON |
OFF |
The E1 link of the Level 3 cascaded BTS can be bypassed. |
|
ON |
ON |
OFF |
OFF |
The E1 link of the Level 4 cascaded BTS can be bypassed. |
|
OFF |
ON |
OFF |
OFF |
The E1 link of the Level 5 cascaded BTS can be bypassed. |
The E1 bypass function is not supported at this version. All the DIP bits of S4 should be set to OFF, and all the DIP bits of S5 should be set to ON.
Table 9describes the DIP switch on the UELP.