LC/PC-FC/PC Single-Mode/Multimode Optical Cable

The LC/PC-FC/PC single-mode/multimode optical cable is an optional cable in the BSC. The number of LC/PC-FC/PC single-mode/multimode optical cables to be configured depends on actual requirements. This cable is used to connect the GOIUA/GOIUB/GOIUP/GOIUT/GOGUA/GOGUB to the ODF or to other NEs. It transmits optical signals.

NOTE:
  • One end of the optical cable connected to the board on the BSC side uses an LC/PC optical connector. The other end of the optical cable can use an LC/PC, FC/PC, or SC/PC connector as required.

  • In practice, two optical cables form one pair. Both ends of each cable in the pair should be attached with temporary labels. If one end of the cable is connected to the TX port, the other end should be connected to the RX port, and vice versa.

  • The TX and RX ends of each optical cable must be connected correctly. Otherwise, signal transmission may fail.

CAUTION:

To prevent signal attenuation and optical return loss as well as to improve transmission quality, you should not use single-mode optical cables and multimode optical cables together to connect telecommunications equipment.

Appearance

Figure 1 shows the LC/PC-FC/PC single-mode/multimode optical cable.

Figure 1 LC/PC-FC/PC single-mode/multimode optical cable

Installation Position

One end of the optical cable with an LC/PC connector is fixed to the GOIUA/GOIUB/GOIUP/GOIUT/GOGUA/GOGUB. The other end of the optical cable with an FC/PC connector is fixed to the ODF, and is then linked to other NEs through a transmission device, or is directly linked to an NE.

Figure 2 shows the installation position of the LC/PC-FC/PC single-mode/multimode optical cable.

Figure 2 Installation position of the LC/PC-FC/PC single-mode/multimode optical cable