LEDs on the Front Panel of the BSC Common Power Distribution Box

The LEDs on the front panel of the BSC common power distribution box are labeled RUN and ALM.

Table 1 describes the LEDs on the front panel of the BSC common power distribution box.

Table 1 LEDs on the front panel of the BSC common power distribution box

LED

Color

Status

Meaning

RUN

Green

On for 1s and off for 1s

The MDMC is operating and communicating with the GSCU.

On for 0.25s and off for 0.25s

The MDMC is not operating or not communicating with the GSCU.

Off

There is no power supply to the MDMC or the power distribution box is faulty.

ALM

Red

Off

There is no alarm.

On

The power distribution box is faulty. The ALM LED, however, is always on during the MDMC self-test. It is an indication that the ALM LED is functional.

NOTE:

When the power distribution box is reset, the RUN and ALM LEDs turn on at the same time. Meanwhile, the monitoring board is performing self-check. As soon as the self-check is complete, the RUN and ALM LEDs turn off. Then, the RUN and ALM LEDs normally display the operating status of the power distribution box.