Connections of Signal Cables in the GBCR (Configuration Type A)

The signal cables in the GBCR consist of the active/standby 75-ohm coaxial cable, active/standby 120-ohm twisted pair cable, optical cable, straight-through cable,inter-GTNU cable, BITS clock cable, Y-shaped clock cable, and PDB monitoring signal cable.

Figure 1 Connections of signal cables in the GBCR (IBM X3650T)

Figure 2 Connections of signal cables in the GBCR (C5210/HP CC3310)

NOTE:
  • Figure 1 and Figure 2 show the connections of signal cables between a GMPS and a GEPS. If there are more than one GEPS, you need to connect each GEPS to the GMPS directly. The connection method is the same as the method of connecting the first GEPS to the GMPS.
  • The types of interface boards, installation positions of cables, and number of cables shown in Figure 1 and Figure 2 are examples. The actual types of interface boards, installation positions of cables, and number of cables depend on the site plan.

Table 1 describes the connections of the signal cables in the GBCR.

Table 1 Signal cables in the GBCR

SN

Description

Connector Type/Installation Position 1

Connector Type/Installation Position 2

Remarks

1

75-ohm coaxial clock cable (or 120-ohm clock conversion cable) connecting the GGCU to the BITS clock port

SMB male connector/CLKIN1 port on the GGCU that is installed in slot 13 of the GMPS

Connector attached to the BITS clock/BITS clock port

Figure 1 shows the clock cables that are connected to the CLKIN1 and CLKIN0 ports. Generally, only one port is used to connect to the BITS clock.

2

75-ohm coaxial clock cable (or 120-ohm clock conversion cable) connecting the GGCU to the BITS clock port

SMB male connector/CLKIN0 port on the GGCU that is installed in slot 13 of the GMPS

Connector attached to the BITS clock/BITS clock port

3

75-ohm coaxial clock cable (or 120-ohm clock conversion cable) connecting the GGCU to the BITS clock port

SMB male connector/CLKIN1 port on the GGCU that is installed in slot 12 of the GMPS

Connector attached to the BITS clock/BITS clock port

4

75-ohm coaxial clock cable (or 120-ohm clock conversion cable) connecting the GGCU to the BITS clock port

SMB male connector/CLKIN0 port on the GGCU that is installed in slot 12 of the GMPS

Connector attached to the BITS clock/BITS clock port

5

Y-shaped clock cable connecting the GGCU to the GSCU

RJ45/CLKOUT port on the GGCU that is installed in slot 12 or 13 of the GMPS

RJ45/CLKIN port on the GSCU that is installed in slot 6 of the GEPS

-

6

Y-shaped clock cable connecting the GGCU to the GSCU

RJ45/CLKOUT port on the GGCU that is installed in slot 12 or 13 of the GMPS

RJ45/CLKIN port on the GSCU that is installed in slot 7 of the GEPS

7

Inter-GTNU cable

DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GMPS

DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GEPS

-

8

Inter-GTNU cable

DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GMPS

DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GEPS

9

E1/T1 cable connecting the EIUa/PEUa to the DDF or other NEs

DB44/E1/T1 port on the EIUa/PEUa that is installed in slot 14 of the GEPS

DDF or other NEs

-

10

E1/T1 cable connecting the EIUa/PEUa to the DDF or other NEs

DB44/E1/T1 port on the EIUa/PEUa that is installed in slot 15 of the GEPS

DDF or other NEs

11

E1/T1 cable connecting the EIUa/PEUa to the DDF or other NEs

DB44/E1/T1 port on the EIUa/PEUa that is installed in slot 14 or 15 of the GEPS

DDF or other NEs

-

12

PDB monitoring signal cable

DB15/port connecting the PDB to a service subrack

DB15/MONITOR port on the lowest subrack

-

13

Optical cable

LC optical port/slot 27 of the GEPS

OIUa in the GTCS, or ODF, or other NEs

-

14

Inter-GSCU Ethernet cable

RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the GMPS

RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the GEPS

-

15

Inter-GSCU Ethernet cable

RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the GMPS

RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the GEPS

16

Inter-GSCU Ethernet cable

RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the GMPS

RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the GEPS

17

Inter-GSCU Ethernet cable

RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the GMPS

RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the GEPS

18

Ethernet cable between the GSCU and the GBAM

RJ45/GBAM

RJ45/10/100/1000BASE-T10 port on the GSCU that is installed in slot 6 of the GMPS

-

19

Ethernet cable between the GSCU and the GBAM

RJ45/GBAM

RJ45/10/100/1000BASE-T10 port on the GSCU that is installed in slot 7 of the GEPS

20

Ethernet cable between the LAN switch and the GBAM

RJ45/Ethernet port on the GBAM

RJ45/Ethernet port on the LAN switch

The GBAM is connected to port 2 on the LAN switch.

21

Ethernet cable between the LAN switch and the LMT computer

RJ45/Ethernet port on the LAN switch

RJ45/LMT computer

The LMT computer is connected to port 22 on the LAN switch.

22

Ethernet cable between the LAN switch and the M2000 (LAN)

RJ45/Ethernet port on the LAN switch

RJ45/Ethernet port on the M2000 (LAN)

The M2000 (LAN) is connected to port 24 on the LAN switch.

23

Ethernet cable between the GBAM and the KVM

DB25 male connector/KVM signal input port

DB15 male connector/GBAM monitor port (PS2 male connector)/Y-shaped KVM mouse port (PS2 male connector)/Y-shaped KVM key port

-

24

Ethernet cable between the LAN switch and the CBC

RJ45/Ethernet port on the LAN switch

RJ45/Ethernet port on the M2000 (LAN)

The CBC is connected to port 20 on the LAN switch.


Huawei Proprietary and Confidential