The signal cables in the GBSR consist of the active/standby 75-ohm coaxial cable, active/standby 120-ohm twisted pair cable, optical cable, straight-through cable, inter-GTNU cable, Y-shaped clock cable, and PDB monitoring signal cable.
Figure 1 shows the connections of the signal cables in the GBSR.
Table 1 describes the connections of the signal cables in the GBSR.
SN |
Description |
Connector Type/Installation Position 1 |
Connector Type/Installation Position 2 |
---|---|---|---|
1 |
PDB monitoring signal cable |
DB15/port connecting the PDB to a service subrack |
DB15/MONITOR port on the lowest subrack |
2 |
Inter-GSCU Ethernet cable |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the main GTCS |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the GTCS |
3 |
Inter-GSCU Ethernet cable |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the main GTCS |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the GTCS |
4 |
Inter-GSCU Ethernet cable |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the main GTCS |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the GTCS |
5 |
Inter-GSCU Ethernet cable |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the main GTCS |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the GTCS |
6 |
Inter-GSCU Ethernet cable |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the main GTCS |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the GTCS |
7 |
Inter-GSCU Ethernet cable |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the main GTCS |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the GTCS |
8 |
Inter-GSCU Ethernet cable |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the main GTCS |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 6 of the GTCS |
9 |
Inter-GSCU Ethernet cable |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the main GTCS |
RJ45/10/100/1000BASE-T port on the GSCU that is installed in slot 7 of the GTCS |
10 |
Inter-GTNU cable |
DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GTCS |
DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GTCS |
11 |
Inter-GTNU cable |
DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GTCS |
DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GTCS |
12 |
Inter-GTNU cable |
DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GTCS |
DB14/TDM port on the GTNU that is installed in slot 4 or 5 of the GTCS |
13 |
E1/T1 cable connecting the EIUa/PEUa to the DDF or other NEs |
DB44/E1/T1 port on the EIUa/PEUa that is installed in slot 14 or 15 of the GTCS |
DDF or other NEs |
14 |
E1/T1 cable connecting the EIUa/PEUa to the DDF or other NEs |
DB44/E1/T1 port on the EIUa/PEUa that is installed in slot 14 or 15 of the GTCS |
DDF or other NEs |
15 |
E1/T1 cable connecting the EIUa/PEUa to the DDF or other NEs |
DB44/E1/T1 port on the EIUa/PEUa that is installed in slot 14 or 15 of the GTCS |
DDF or other NEs |
16 |
Optical cable |
LC optical port/RX/TX port on the OIUa that is installed in slot 27 of the GTCS |
OIUa of the GMPS/GEPS or ODF |