Querying BTS Running Status

This describes how to query the running status of the BTSs or cells under a BSC.

Prerequisites

Context

You can query the running status parameters of the BTSs or of cells through the LMT. Table 1 lists the running status parameters of the BTSs.

Table 1 Description of BTS running status parameters

Parameter

Description

Normal OML Link

Indicates whether the OML link between the current site and BSC is normal.

BTS Initialized

Indicates whether the current site is initialized.

Cell Initialized

Indicates whether the cell under the current site is initialized.

Block Automatically

Indicates whether a fault occurs to the current site that is blocked automatically.

Channel Fault

Indicates whether a channel fault occurs to the current site.

BCCH Mutual Aid

Indicates whether the mutual aid takes place between the primary BCCH and other TRXs when the TRX where the BCCH resides is exceptional.

BT Hop Mutual Aid

Indicates that a fault occurs to the TRX that joins in baseband FH or the BCCH mutual aid occurs in the cell.

Channel Type Dynamically Changed

Indicates whether the channel type of the current site changes.

TCH->SDCCH, SDCCH->TCH, TCH/H->TCH/F, TCH/F->TCH/H, dynamic PDTCH->TCH, and TCH->dynamic PDTCH.

Management Authority in the Near End

Indicates whether the local site maintenance has got the local management authority.

Board Fault

Indicates whether the board in the current site is running normally.

Board not Configured

Indicates whether the board in position is configured with software information.

Alarm

Indicates whether alarms occur in the current site.

Block Manually

Indicates whether the management status of the current site is set to Block Manually.

Alarm Shielded

Indicates whether the alarm shield is set for the alarms in the current site.

Frequency Scanning

Indicates whether the cell in the current site is in frequency scanning status.

Table 2 lists the running status parameters of the cells.

Table 2 Description of cell running status parameters

Parameter

Description

Cell Initialized

Indicates whether the current cell is initialized.

Block Automatically

Indicates whether the current cell is blocked automatically due to the TRX fault.

Channel Fault

Whether channel link is faulty.

BCCH Mutual Aid

Indicates whether the mutual aid takes place between the primary BCCH and other TRXs when the TRX where the BCCH resides is exceptional.

BT Hop Mutual Aid

Indicates that a fault occurs to the TRX that joins in baseband FH or the BCCH mutual aid occurs in the cell.

Channel Type Dynamically Changed

Indicates whether channel switchover occurs in the cell.

TCH->SDCCH, SDCCH->TCH, TCH/H->TCH/F, TCH/F->TCH/H, dynamic PDTCH->TCH, and TCH->dynamic PDTCH.

Block Manually

Indicates whether the management status of the current site is set to Block Manually.

Frequency Scanning

Indicates whether the cell is in frequency scanning status.

Procedure

Related tasks
Using the Local Maintenance Terminal

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.