Tracing OML Messages on the Abis Interface

This describes how to trace operation and maintenance link(OML) signaling messages on the Abis interface on the LMT. The messages consist of common message and OM message.

Prerequisites

Context

Tracing the OML messages at Abis interface based on sites (a maximum of 16 sites)

For details of Message Type, refer to Message Types.

For details of Tracing Mode, refer to Tracing Modes.

The following description is based on the configuration using the GOMU.

Procedure

  1. On the Trace & Monitor tab page, choose Trace > Trace Message on the Abis Interface > OML Message. A dialog box is displayed, as shown in Figure 1.

    This message is the display record of the interaction between the BSC and BTS maintenance signaling and is an important measure of identifying exceptions in a site.

    Figure 1 Trace OML Message on the Abis Interface dialog box

  2. Set Message Type, Color, and Tracing Mode. Select cells from the Candidate Cells box and add them to the Selected Cells box.
  3. Click OK.

Result

Postrequisite

You can double-click a message to view the detailed information.

Right-click the message to be analyzed. The shortcut menu provides the following options:
  • Clear Message: Clear the displayed messages.
  • Stop Scroll: Stop scrolling the displayed messages.
  • Stop Trace: Stop the current tracing task.
  • Restart Trace: Restart the tracing task.
  • View Task: View the established tracing task.
  • Search: Search for the specified character string in the displayed messages.
  • Save Selection: Save the selected messages.
  • Save All: Save all the traced messages.
Related concepts
Message Types
Tracing Modes

Huawei Proprietary and Confidential