Tracing Application Messages on the Pb Interface

This describes how to trace application messages on the Pb interface on the LMT. The messages consist of paging message, confusion message, PCIC message, and other messages.

Prerequisites

Context

The application messages on the Pb interface can be traced. A maximum of 16 cells are supported.

For details of Message Type, refer to Message Types.

For details of Tracing Mode, refer to Tracing Modes.

The following description is based on the configuration using the GOMU.

Procedure

  1. On the Trace & Monitor tab page, choose Trace > Trace Message on the Pb Interface > Application Message. A dialog box is displayed, as shown in Figure 1.

    Figure 1 Trace Application Message on the Pb Interface dialog box

  2. Set Message Type, Location, Color, and Tracing Mode. Select cells from the Candidate Cells box and add them to the Selected Cells box.
  3. Click OK.

Result

Postrequisite

You can double-click a message to view the detailed information.

Right-click the message to be analyzed. The shortcut menu provides the following options:
  • Clear Message: Clear the displayed messages.
  • Stop Scroll: Stop scrolling the displayed messages.
  • Stop Trace: Stop the current tracing task.
  • Restart Trace: Restart the tracing task.
  • View Task: View the established tracing task.
  • Search: Search for the specified character string in the displayed messages.
  • Save Selection: Save the selected messages.
  • Save All: Save all the traced messages.
Related concepts
Message Types
Tracing Modes