A configuration command that adds a local operator account into the configuration database. Before operating the NE, a local operator must have a valid account. The keyword of this command is "Operator".
1. A super user account "admin" is set in the system. This account can execute all commands and cannot be modified or removed.
2. The "emscomm" is a reserved field in the system. You cannot add a local operator whose user name is emscomm.
3. Only the system administrator (admin), operators in the management level, and operators in the customized level that are authorized to add operator's rights can execute this command.
4. The operation time limit includes the data limit, week limit, time segment limit, and no limit. The operation time limit for an operator is the intersection of the date limit, week limit, and time segment limit.
5. If the operation time limit takes the local time as the standard and when the local time changes because of the time zone or DST, the operation time limit takes the updated local time as the standard.
ID | Name | Description |
---|---|---|
OP | Operator | Meaning: local operator account Value range: 1-32 characters Explanation: An operator account is case insensitive and it cannot be omitted or repeated with others.This parameter consists of only letters, digits, and underlines. It must start with a letter. Default value: None |
DESCRP | Description | Meaning: description of an operator Value range: 1-127 characters Explanation: This parameter specifies the account of an operator. Default value: None |
PWD | Password | Meaning: password of a local operator Value range: 6-32 characters Explanation: 1. This parameter specifies the password of a local operator. The password is displayed in the form of *. 2. The length of a password ranges from 6 to 32 characters.The password cannot contain the following characters: comma (,), semicolon (;), equal mark (=), double quotation marks ("), single quotation marks ('), and backward slash (\). 3. The changed password takes effect when the operator logs in to the system next time. 4. The minimum length of the password is subject to the password policy. If the password policy specifies that the minimum length of the password is eight characters, then the actual value range of the password is 8 to 32 characters, instead of 6 to 32 characters. 5. Set the password in compliance with the password setting policy. For details, see the LST PWDPOLICY command. Default value: None |
CFM | Confirm password | Meaning: confirmed password of the local operator Value range: 6-32 characters Explanation: 1. This parameter specifies the password of a local operator. The password is displayed in the form of *. 2. The length of a password ranges from 6 to 32 characters.The password cannot contain the following characters: comma (,), semicolon (;), equal mark (=), double quotation marks ("), single quotation marks ('), and backward slash (\). 3. The changed password takes effect when the operator logs in to the system next time. 4. The minimum length of the password is subject to the password policy. If the password policy specifies that the minimum length of the password is eight characters, then the actual value range of the password is 8 to 32 characters, instead of 6 to 32 characters. 5. Set the password in compliance with the password setting policy. For details, see the LST PWDPOLICY command. Default value: None |
UG | User group | Meaning: user group level of a local operator Value range: Administrator(Administrator), Operator(Operator), User(User), Guest(Guest), Custom(Custom) Explanation: This parameter defines the user group for an operator to limit the operation rights of the operator. Guest level: An operator in the guest level can only view data. User level: In addition to the right of the Guest, the operator can maintain the system. Operator level: In addition to the rights of the User, the operator can configure data. Administrator level: In addition to the rights of the Operator, the operator can manage users. Custom level: The rights of the operator with this level are defined by the operator with the Administrator level. Except for the Custom level, the first four levels are fixed. That is, the rights of the first four levels cannot be added or reduced. Default value: Guest(Guest) |
CG | Command group | Meaning: command group that the local operator can execute Value range: G_0-G_31 Explanation: 1. This parameter is valid only when the User group parameter is set to Custom(Custom). The meanings of command groups are as follows: G_0 = System information query G_1 = System information management G_2 = Configuration data query G_3 = Common data configuration G_4 = Advanced data configuration G_5 = BTS maintenance query G_6 = Basic BTS maintenance G_7 = Advanced BTS maintenance G_8 = BSC maintenance query G_9 = Basic BSC maintenance G_10 = Advanced BSC maintenance G_11 = Alarm query G_12 = Alarm management G_13 = BSC software management G_14 = BOOTROM management G_15 = License management G_16 = Interface tracing G_17 = Performance management G_18 = Performance query G_19 = Integrated equipment G_20 = PSOM project team G_21 = PSOM project team G_22 = PSOM project team G_20 - G_31: User-defined command groups 2. The value behind the selected command group in the command line can be: (1) 0: The command group is removed from the authority of the operator. (2) 1: The command group is added to the authority of the operator. Default value: None |
DATE | Date limit | Meaning: limit on the operation date of an operator Value range: NOLIMIT(No Limit), LIMIT(Limit) Explanation: This parameter specifies whether to limit the operation date of an operator. Default value: NOLIMIT(No Limit) |
STD | Start date | Meaning: start date Value range: 1. Year: 2000-2050 2. Month: 1-12 3. Day: 1-31 Explanation: 1. This parameter specifies the start date of the operation for the local operator. 2. If no value is input, it indicates that the start date is not limited. 3. The start date should be in the YYYY&MM&DD format. Default value: None |
ETD | End date | Meaning: end date Value range: 1. Year: 2000-2050 2. Month: 1-12 3. Day: 1-31 Explanation: 1. This parameter specifies the end date of the operation for the local operator. 2. If no value is input, it indicates that the end date is not limited. 3. The end date should be in the YYYY&MM&DD format. Default value: None |
TIME | Time limit | Meaning: time limit Value range: NOLIMIT(No Limit), LIMIT(Limit) Explanation: This parameter specifies whether to limit the operation time of an operator. Default value: NOLIMIT(No Limit) |
STT | Start time | Meaning: start time Value range: 1. Hour: 0-23 2. Minute: 0-59 3. Second: 0-59 Explanation: 1. This parameter specifies the start time of the operation for the local operator. 2. If no value is input, it indicates that the start time is not limited. 3. The start time should be in the HH&MM&SS format. Default value: None |
ETT | End time | Meaning: end time Value range: 1. Hour: 0-23 2. Minute: 0-59 3. Second: 0-59 Explanation: 1. This parameter specifies the end time of the operation for the local operator. 2. If no value is input, it indicates that the end time is not limited. 3. The end time should be in the HH&MM&SS format. Default value: None |
WEEK | Week limit | Meaning: limit on the weekday of the operation Value range: NOLIMIT(No Limit), LIMIT(Limit) Explanation: This parameter specifies whether to limit the weekday of the operation. If the weekday needs to be limited, see parameter "Week". Default value: NOLIMIT(No Limit) |
WK | Week | Meaning: weekday Value range: SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday), THU(Thursday), FRI(Friday), SAT(Saturday) Explanation: 1. This parameter specifies the weekday(s) on which the operator can perform the operation. 2. If no value is input, it indicates that the weekday is not limited. 3. More than one weekday can be selected. Default value: None |
1. Add an operator account A with the Guest level. Only the operator account and password are input. Other parameters are default values: ADD OP: OP="A", PWD="********", CFM="********", UG=GUEST, DATE=NOLIMIT, TIME=NOLIMIT, WEEK=NOLIMIT; 2. Add an operator "zhangsan" with the Custom level. The operation time limit is 8:00 a.m.-10:00 a.m. every Sunday from June to August, 2004. The operation rights include query and management on the equipment: ADD OP: OP="zhangsan", PWD="********", CFM="********", UG=CUSTOM, CG=G_7-1&G_8-1, DATE=LIMIT, STD=2004&06&01, ETD=2004&08&31, TIME=LIMIT, STT=08&00&00, ETT=10&00&00, WEEK=LIMIT, WK=SUN;