1. On a specified port in a specified slot of a specified subrack on the Pb interface, you can configure the signaling link only after an E1/T1 link is configured and the E1/T1 link has idle timeslots.
2. The value of Congestion Start Threshold must be greater than the value of Congestion End Threshold.
ID | Name | Description |
---|---|---|
SRN | Subrack No. | Meaning:Subrack No. Value range:0~11 Explanation:This parameter indicates the subrack number of the Pb Signaling Link. Default value:None |
SN | Slot No. | Meaning:Slot No. Value range:0~27 Explanation:This parameter indicates the slot number of the Pb Signaling Link. Default value:None |
PN | Port No. | Meaning:Port No. Value range:0~83 Explanation:This parameter specifies the E1/T1 port number of the Pb Signaling Link. Default value:None |
TSNO | Timeslot No. | Meaning:Timeslot No. Value range:1~31 Explanation:This parameter specifies the E1/T1 timeslot number of the Pb Signaling Link. Default value:None |
TEI | TEI | Meaning:TEI Value range:0~127 Explanation:This parameter specifies the terminal equipment identifier on the link layer. Default value:63 |
CGST | Congestion Start Threshold | Meaning:Congestion Start Threshold Value range:30~100 Explanation:This parameter specifies the congestion start threshold of the Pb Signaling Link. Default value:90 |
CGET | Congestion End Threshold | Meaning:Congestion End Threshold Value range:20~90 Explanation:This parameter specifies the congestion end threshold of the Pb Signaling Link. Default value:60 |