Clear BC Statistics(CLR BC)

Function

An OM command that clears the BC statistics information.

Note

None

Parameters

ID Name Description
SRN Subrack No.

Meaning: subrack number

Value range: 0-11

Explanation:

1. This parameter specifies the subrack number of the BC.

2. The subrack number uniquely identifies a subrack.

Default value: None

SN Slot No.

Meaning: slot number

Value range: 0-27

Explanation:

1. This parameter specifies the slot number of the BC.

2. The subrack number and slot number uniquely identify a board.

Default value: None

PN Port No.

Meaning: port number

Value range: 0-31

Explanation: This parameter specifies the port number of the BC.

Default value: None

BCID BC Id

Meaning: BC ID

Value range: 0-255

Explanation: This parameter specifies the BC ID.

Default value: None

Example

Clear the information of BC statistics (Subrack No. = 0; Slot No. = 22; Port No. =0; BC Id = 0):
CLR BC: SRN=0, SN=22, PN=0, BCID=0;