1. The communication between the MML Client and the BSC is normal.
2. The communication between the BSC and the BTS is normal.
3. The power module is in position and runs normally.
4. The PMU-type board is configured in the BTS.
ID | Name | Description |
---|---|---|
IDXTYPE | Index Type | Meaning: index type Value range: BYNAME(By Name), BYIDX(By Index) Explanation: The value BYNAME(By Name) indicates the query based on the BTS name and the value BYIDX(By Index) indicates the query based on the BTS index. Default value: None |
BTSIDX | BTS Index | Meaning: BTS index Value range: 0-2047 Explanation: 1. This parameter specifies the index of a BTS. Each BTS is numbered uniquely in a BSC. 2. This parameter specifies the BTS index for the system operation. BTS index specifies a global BTS index. 3. This parameter is mandatory if BYIDX(By Index) is selected for the Index Type of the BTS. Default value: None |
BTSNAME | BTS Name | Meaning: BTS name Value range: 1-32 characters Explanation: 1. This parameter specifies the name of a BTS. Each BTS is named uniquely in a BSC. 2. This parameter specifies the BTS name for the system operation. BTS name specifies a global name of the BTS. 3. This parameter is mandatory if BYNAME(By Name) is selected for Index Type of the BTS. Default value: None |
SRN | Subrack No. | Meaning: subrack number of the board Value range: 0-53 Explanation: This parameter specifies the number of the subrack where a BTS board is located. The subrack number is unique in a site. Default value: None |
SN | Slot No. | Meaning: slot number of the board Value range: 0-23 Explanation: This parameter specifies the number of the slot in which a BTS board is located. Default value: None |
Query the status of the power module (Index Type = BYIDX; BTS Index = 0; Subrack No. = 0; Slot No. = 4): DSP BTSBATT:IDXTYPE=BYIDX,BTSIDX=0,SRN=0,SN=4; The result is as follows: +++ HUAWEI 18.06.07 09:13:07 O&M #1320 %% DSP BTSBATT:IDXTYPE=BYIDX,BTSIDX=0,SRN=0,SN=4;%% RETCODE = 0 Operation succeeded GET BATTINFO Result ------------------- Subrack No. = 0 Slot No. = 0 Current Limiting Coefficient of Battery Charging = 45.54 Volume of Assembled Battery 1[AH] = 12.80 Volume of Assembled Battery 2[AH] = 13.70 Suits of Assembled Battery = 2 Timed Boost Charging Interval[day] = 3 Maximum Value of the Assembled Battery 1 Temperature Measurement Range[C] = 23.07 Minimum Value of the Assembled Battery 1 Temperature Measurement Range[C] = 12.08 High Temperature Alarm Setting Value of the Assembled Battery 1[C] = 13.26 Low Temperature Alarm Setting Value of the Assembled Battery 1[C] = 14.70 Maximum Value of the Assembled Battery 2 Temperature Measurement Range[C] = 15.38 Minimum Value of the Assembled Battery 2 Temperature Measurement Range[C] = 17.06 High Temperature Alarm Setting Value of the Assembled Battery 2[C] = 19.78 Low Temperature Alarm Setting Value of the Assembled Battery 2[C] = 13.54 Coefficient of Temperature Compensation[mV] = 17.56 Temperature foundation for Battery Charging Voltage Compensation[C] = Temperature sensor 1 (Number of results = 1) --- END
Domain Name | Description |
---|---|
Current Limiting Coefficient of Battery Charging | Current limiting coefficient of battery charging |
Volume of Assembled Battery 1[AH] | Volume of assembled battery group 1 [AH] |
Volume of Assembled Battery 2[AH] | Volume of assembled battery group 2 [AH] |
Suits of Assembled Battery | Suits of assembled battery group |
Timed Boost Charging Interval [Day] | Timed boost charging interval [Day] |
Maximum Value of the Assembled Battery 1 Temperature Measurement Range[C] | Maximum value of the assembled battery group 1 temperature measurement range [C] |
Minimum Value of the Assembled Battery 1 Temperature Measurement Range[C] | Minimum value of the assembled battery group 1 temperature measurement range [C] |
High Temperature Alarm Setting Value of the Assembled Battery 1[C] | High temperature alarm setting value of the assembled battery group 1 [C] |
Low Temperature Alarm Setting Value of the Assembled Battery 1[C] | Low temperature alarm setting value of the assembled battery group 1 [C] |
Maximum Value of the Assembled Battery 2 Temperature Measurement Range[C] | Maximum value of the assembled battery group 2 temperature measurement range [C] |
Minimum Value of the Assembled Battery 2 Temperature Measurement Range[C] | Minimum value of the assembled battery group 2 temperature measurement range [C] |
High Temperature Alarm Setting Value of the Assembled Battery 2[C] | High temperature alarm setting value of the assembled battery group 2 [C] |
Low Temperature Alarm Setting Value of the Assembled Battery 2[C] | Low temperature alarm setting value of the assembled battery group 2 [C] |
Coefficient of Temperature Compensation[mV] | Coefficient of temperature compensation [mV] |
Temperature foundation for Battery Charging Voltage Compensation[C] | Temperature foundation for battery charging voltage compensation [C] |