ID | Name | Description |
---|---|---|
SRN | Subrack No. | Meaning: subrack number Value range: 0-11 Explanation: 1. This parameter specifies the subrack number of the DSP link. 2. The subrack number uniquely identifies a subrack. Default value: None |
SN | Slot No. | Meaning: slot number Value range: 0-27 Explanation: 1. This parameter specifies the slot number of the DSP link. 2. The subrack number and slot number uniquely identify a board. Default value: None |
DSPNO | DSP No. | Meaning: DSP number Value range: 0-21 Explanation: This parameter specifies the number of the DSP. Default value: None |
LINKNO | Link No. | Meaning: link number Value range: 0-191 Explanation: This parameter specifies the link number of the DSP. Default value: None |
1. Query the status of a DSP link (Subrack No. = 0; Slot No. = 0; DSP No. = 0), and do not set the Link No.: DSP DSPLINK: SRN=0, SN=10, DSPNO=0; The result is as follows: +++ HUAWEI 2008-07-18 08:38:24 O&M #38867 %%DSP DSPLINK: SRN=0, SN=10, DSPNO=0;%% RETCODE = 0 Operation succeeded Query DSP link state --------------- Subrack No. Slot No. DSP No. DSP Link No. DSP Link State Link Assignment State Link Synchronization State 0 10 0 0 No Loopback Normal and Not Assigned Inactive 0 10 0 1 No Loopback Normal and Not Assigned Inactive 0 10 0 2 No Loopback Normal and Not Assigned Inactive 0 10 0 3 No Loopback Normal and Not Assigned Inactive 0 10 0 4 No Loopback Normal and Not Assigned Inactive (Number of results = 5) --- END
Domain Name | Description |
---|---|
Subrack No. | Subrack number of the DSP link |
Slot No. | Slot number of the DSP link |
DSP No. | DSP number |
DSP Link No. | DSP link number |
DSP Link State | DSP link status, value range: No Loopback , Local Loopback, Auxiliary Loopback. No Loopback indicates that the DSP link is normal; Local Loopback indicates that the signals that should be in the transmitting direction are in the receiving direction as the received data; Auxiliary Loopback indicates that the DSP link facilitates other loopback. |
Link Assignment State | Link assignment status, value range: Unavailable, Normal and Not Assigned, Assigned. Unavailable indicates that the DSP link is not available; Normal and Not Assigned indicates that the DSP link is normal and idle; Assigned indicates that the DSP link is occupied. |
Link Synchronization State | Link synchronization status, value range: Unsynchronized, Synchronized, Out-of-Sync., Test, Inactive. Unsynchronized indicates that the link is in the initial status; Synchronized indicates that the link on the Abis interface is synchronized with the BTS; Out-of-Sync. indicates that the synchronization fails and the link on the Abis interface is in the out-of-synchronization status; Test indicates that the link is used for test; Inactive indicates that the link is not used. |