Display PVC Statistics(DSP PVC)

Function

An OM command that queries the information about PVC statistics.

Note

None

Parameters

ID Name Description
SRN Subrack No.

Meaning: subrack number

Value range: 0-11

Explanation:

1. This parameter specifies the subrack number of the PVC.

2. The subrack number uniquely identifies a subrack.

Default value: None

SN Slot No.

Meaning: slot number

Value range: 0-27

Explanation:

1. This parameter specifies the slot number of the PVC.

2. The subrack number and slot number uniquely identify a board.

Default value: None

PN Port No.

Meaning: port number

Value range: 0-31

Explanation: This parameter specifies the port number of the PVC.

Default value: None

BCID BC Id

Meaning: BC ID

Value range: 0-255

Explanation: This parameter identifies the BC ID of the PVC.

Default value: None

DLCI DLCI

Meaning: data link connection ID

Value range: 16-1007

Explanation: data link connection ID of the PVC

Default value: None

Example

Query the information about PVC statistics (Subrack No. = 0; Slot No. = 22; Port No. = 0; BC Id = 0; DLCI = 66):
DSP PVC: SRN=0, SN=22, PN=0, BCID=0, DLCI=66;
The result is as follows:
+++    HUAWEI        2008-07-18 14:09:09
O&M    #7049
%%DSP PVC: SRN=0, SN=22, PN=0, BCID=0, DLCI=66;%%
RETCODE = 0  Operation succeeded

        Number of Sent Frames  =  9420
    Number of Received Frames  =  4209
    Number of Discarded Bytes  =  0
         Number of Sent Bytes  =  437700
     Number of Received Bytes  =  13198
   Number of Discarded Frames  =  0
Number of Reverse Congestions  =  0
(Number of results = 1)

---    END

Output Description

Domain Name Description
Number of Sent Frames

Number of frames sent on the PVC

Number of Received Frames

Number of frames received from the SGSN on the PVC

Number of Discarded Bytes

Number of discarded bytes

Number of Sent Bytes

Number of bytes sent on the PVC

Number of Received Bytes

Number of bytes received from the SGSN on the PVC

Number of Discarded Frames

Number of discarded frames

Number of Reverse Congestions

Reverse congestion times

Related reference
Block PTPBVC(BLK PTPBVC)
Clear PVC Statistics(CLR PVC)

Huawei Proprietary and Confidential