Exchange BTS Port Timeslot(EXC BTSTS)

Function

A configuration command that performs timeslot switching on a BTS.

Note

1. The MML client must communicate with the BSC properly.

2. After the switching of the OML timeslot is complete and the OML port changes, the main port of the BTS is changed to be the OML port.

3. In 64 kbit/s multiplexing mode, the switching of the entire 64 kbit/s timeslot must be implemented.

Parameters

ID Name Description
IDXTYPE Index Type

Meaning:Index Type

Value range:BYNAME(By Name),BYIDX(By Index)

Explanation:Index type.

Default value:None

BTSIDX BTS Index

Meaning:BTS Index

Value range:0~2047

Explanation:This parameter specifies the index number of a BTS. Each BTS is numbered uniquely in a BSC.

Default value:None

BTSNAME BTS Name

Meaning:BTS Name

Value range:1-32 characters

Explanation:This parameter specifies the name of a BTS. The name of each BTS is unique in a BSC. Excluding the invalid characters ';',',','"','''','=','\','%%','+++','&','#'.

Default value:None

PN1 Port 1 NO.

Meaning:Port 1 NO.

Value range:0~23

Explanation:This parameter specifies the port number of the BTS whose timeslots are to be switched.

Default value:None

STARTTS1 Start Timeslot NO. of Port 1

Meaning:Start Timeslot NO. of Port 1

Value range:1~31

Explanation:This parameter indicates the number of the E1 timeslot transmitted on a Ater signaling link over the Ater interface.

Generally, an E1 link has 32 timeslots. Timeslot 0 is specially used for synchronization.

The transmission rate of each timeslot is 64 kbit/s. One timeslot generally consists of eight sub-timeslots (the transmission rate of each sub-timeslot is 8 kbit/s) or four sub-timeslots (the transmission rate of each sub-timeslot is 16 kbit/s).

This parameter cannot be blank.

You can modify the Timeslot No. of only idle E1 timeslots on the same GEIUT or GOIUT.

Default value:None

STARTSUBTS1 Start Sub Timeslot NO. of Port 1

Meaning:Start Sub Timeslot NO. of Port 1

Value range:0(0),2(2),4(4),6(6)

Explanation:One E1 timeslot generally consists of eight sub-timeslots (the transmission rate of each sub-timeslot is 8 kbit/s) or four sub-timeslots (the transmission rate of each sub-timeslot is 16 kbit/s).

The eight sub-timeslots are numbered 0-7 and the four sub-timeslots are numbered 0-3.

Default value:None

SUBTSNUM Number of Sub Timeslot

Meaning:Number of Sub Timeslot

Value range:1~124

Explanation:Each timeslot of the E1 port is divided into eight sub-timeslots (8 kbit/s per sub-timeslot) or four sub-timeslots (16 kbit/s per sub-timeslot).

In the case of eight sub-timeslots, the sub-timeslots are numbered 0 to 7.

In the case of four sub-timeslots, the sub-timeslots are numbered 0 to 3.

Default value:None

PN2 Port 2 NO.

Meaning:Port 2 NO.

Value range:0~23

Explanation: This parameter specifies the port number of the BTS whose timeslots are to be switched.

Default value:None

STARTTS2 Start Timeslot NO. of Port 2

Meaning:Start Timeslot NO. of Port 2

Value range:1~31

Explanation:This parameter specifies the timeslot number of an E1 port on the GEIUT/GOIUT occupied by the Ater signaling link.

Each E1 port has 32 timeslots and each timeslot works at 64 kbit/s. Each timeslot is divided into eight sub-timeslots (8 kbit/s per sub-timeslot) or four sub-timeslots (16 kbit/s per sub-timeslot). Timeslot 0 is mainly used for synchronization. Generally, this timeslot is unused.

The timeslot number of the Ater signaling link cannot be null. The timeslot number can be modified but it must be an unoccupied timeslot on the same GEIUT or GOIUT.

Default value:None

STARTSUBTS2 Start Sub Timeslot NO. of Port 2

Meaning:Start Sub Timeslot NO. of Port 2

Value range:0(0),2(2),4(4),6(6)

Explanation:Each timeslot of the E1 port is divided into eight sub-timeslots (8 kbit/s per sub-timeslot) or four sub-timeslots (16 kbit/s per sub-timeslot).

In the case of eight sub-timeslots, the sub-timeslots are numbered 0 to 7.

In the case of four sub-timeslots, the sub-timeslots are numbered 0 to 3.

Default value:None

Example

Exchange BTS port timeslot(Index Type = BYIDX(By Index); BTS Index = 0; Port1 NO. = 0; Start Timeslot NO. of Port1 = 0; Start Sub Timeslot NO. of Port1 = 0; Number of Sub Timeslot = 12; Port2 NO. = 1; Start Timeslot NO. of Port2 = 10; Start Sub Timeslot NO. of Port1 = 0;):
EXC BTSTS: IDXTYPE=BYIDX, BTSIDX=0, PN1=0, STARTTS1=10, STARTSUBTS1=0, SUBTSNUM=12, PN2=1, STARTTS2=10, STARTSUBTS2=0;

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.