List Active Alarms Triggering Alarm Box(LST BOXALM)

Function

List the driving alarm of the current alarm box After the command is executed, all levels information of the driving alarm is displayed.

Note

If no audible alarm is triggered on the alarm box, the number of returned active alarms is 0.

Parameters

ID Name Description
BOXLOC Alarm Box Position

Meaning: position of the alarm box

Value range: loc(Local), omu(OMU)

Explanation:

1. The value loc(Local) indicates that the alarm box is connected to the serial port on the local PC; the value omu(OMU) indicates that the alarm box is connected to the OMU.

2. This parameter specifies the position of the alarm box, and is used to query the record of the active alarms that trigger an audible alarm on the alarm box.

Default value: loc(Local)

Example

1.List the driving alarm of the current alarm box  
LST BOXALM:BOXLOC=loc;
The result is displayed as follows:
+++    HUAWEI        2008-07-16 08:37:36
O&M    #486
%%LST BOXALM:BOXLOC=loc;%%
RETCODE = 0  Operation succeeded

ALARM  2           Fault     Critical        BSC6000   21551      Communication
     Sync serial No.  =  3
          Alarm name  =  Ater OML Broken Alarm
   Alarm raised time  =  2008-07-15 17:01:03
       Location info  =  Index No.=10,Subrack No.=12, Slot No.=25,E1/T1 Port No.=29

ALARM  3           Fault     Critical        BSC6000   21551      Communication
     Sync serial No.  =  4
          Alarm name  =  Ater OML Broken Alarm
   Alarm raised time  =  2008-07-15 17:01:03
       Location info  =  Index No.=10,Subrack No.=12, Slot No.=25,E1/T1 Port No.=39

(Number of results = 2)

---    END

Output Description

Domain Name Description
Serial No.

Serial number of the alarm record

Alarm Type

Type of the alarm.FLT: fault alarm,EVT: event alarm

Alarm Severity

Severity of the alarm. CRITICAL: critical alarm,MAJOR: major alarm,MINOR: minor alarm,WARNING: warning

Alarm Source

Source where the alarm is generated

Alarm ID

Uniquely identifying a type of alarm

Event Type

Event type of the alarm record. power(power system), env(environment system), sig(signaling system), trunk(relay system), hardware(hardware system), software(software system), run(running system), comm(communication system), service(QoS), handle(Processing Error).

Sync serial No.

Sync serial No.

Alarm name

Alarm name

Alarm raised time

Alarm raised time

Location info

Location informaton of the alarm


Huawei Proprietary and Confidential