List SS7 Signaling Link(LST N7LNK)

Function

An OM command that queries the configuration of the SS7 signaling link.

To query all the SS7 signaling links in a specific BM, set BM Subrack No. and Service Mode.

To query a specific SS7 signaling link, set BM Subrack No., Service Mode, and MTP3 Link No.. When the Service Type is set to TOGETHER(BM/TC Together), set A Interface Slot No..

Note

None

Parameters

ID Name Description
BMSRN BM Subrack No.

Meaning:BM Subrack No.

Value range:0~11

Explanation: Mtp2FramNo.

Default value:None

SERVICEMODE Service Mode

Meaning:Service Mode

Value range:SEPARATE(BM/TC Separate),TOGETHER(BM/TC Together)

Explanation: Index Type.

Default value:None

ASN A Interface Slot No.

Meaning:A Interface Slot No.

Value range:0~27

Explanation: This parameter specifies the number of the slot where the A interface board (configured with MTP2LINK) is located.

Default value:None

LINKNO MTP3 Link No.

Meaning:MTP3 Link No.

Value range:0~31

Explanation: LinkNo.

Default value:None

Example

1. Query the configuration of the SS7 signaling link (BM Subrack No. = 0; Service Mode = SEPERATE(BM/TC Seperate)):
LST N7LNK: BMSRN=0, SERVICEMODE=SEPERATE;
The result is as follows:
+++    HUAWEI        2008-07-04 01:11:20
O&M    #3227
%%LST N7LNK: BMSRN=0, SERVICEMODE=SEPARATE;%%
RETCODE = 0  Operation succeeded

LST N7LNK Result
----------------
MTP3 Link No  AsubLinkIndex  BM Subrack No  Ater Interface Timeslot Mask      LinkType  AFramNo  ASlotNo  AE1LinkNo  A Interface Timeslot Mask         CT1    CT2    CT3   CT4e  CT4n  CT5  CT6   CT7   CT9  SPUSLOT  SPUCPU  STPC/DPC used by signaling link(Hex)  SLC  SLCSEND  PRI  SATFLAG      CONGESTIONBEGIN  CONGESTIONEND  TESTCODE  TESTCODELEN

1             0              0              00100000000000000000000000000000  64K       1        16       1          00100000000000000000000000000000  45000  30000  1300  500   8200  100  5000  1500  100  0        2       H'2                                   5    5        0    Normal Link  80               70             165       6          
0             0              0              01000000000000000000000000000000  64K       1        16       0          01000000000000000000000000000000  45000  30000  1300  500   8200  100  5000  1500  100  0        1       H'2                                   3    3        0    Normal Link  80               70             165       6          
(Number of results = 2)


---    END
2. Query the configuration of the SS7 signaling link (BM Subrack No. = 0; Service Mode = TOGETHER(BM/TC Together); A Interface Slot No. = 15; MTP3 Link No. = 0):
LST N7LNK: BMSRN=0, SERVICEMODE=TOGETHER, ASN=14, LINKNO=0;
The result is as follows:
+++    HUAWEI        2008-07-04 01:17:56
O&M    #3328
%%LST N7LNK: BMSRN=0, SERVICEMODE=TOGETHER, ASN=15, LINKNO=0;%%
RETCODE = 0  Operation succeeded

LST N7LNK Result
----------------
                        MTP3 Link No  =  0
                       BM Subrack No  =  0
                            LinkType  =  64K
                             AFramNo  =  0
                             ASlotNo  =  15
                           AE1LinkNo  =  0
           A Interface Timeslot Mask  =  01000000000000000000000000000000
                                 CT1  =  45000
                                 CT2  =  30000
                                 CT3  =  1300
                                CT4e  =  500
                                CT4n  =  8200
                                 CT5  =  100
                                 CT6  =  5000
                                 CT7  =  1500
                                 CT9  =  100
                             SPUSLOT  =  0
                              SPUCPU  =  1
STPC/DPC used by signaling link(Hex)  =  H'2
                                 SLC  =  3
                             SLCSEND  =  3
                                 PRI  =  0
                             SATFLAG  =  Normal Link
                     CONGESTIONBEGIN  =  80
                       CONGESTIONEND  =  70
                            TESTCODE  =  165
                         TESTCODELEN  =  6
(Number of results = 1)


---    END

Output Description

For details, see the parameter description of the ADD N7LNK and MOD N7LNK commands.
Related reference
Add SS7 Signaling Link(ADD N7LNK)

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.