List Software Parameters of PS Domain(LST PSSOFTPARA)

Function

An OM command that queries the configuration of the PS-domain software parameters.

Note

None

Parameters

None.

Example

Query PS-domain software parameters:
LST PSSOFTPARA:;

The result is as follows:
+++    HUAWEI        2008-11-19 12:23:32
O&M    #1459
%%LST PSSOFTPARA:;%%
RETCODE = 0  Operation succeeded

LST PSSOFTPARA Result
---------------------
             Allocate Two Timeslots Switch for MS over Uplink  =  Allocate Two Timeslots
                                     Allow E Down G Up Switch  =  Open
                      A Interface Collaboration Paging Switch  =  Close
                                            DSP Kickoff Timer  =  180
                                            DSP Recover Timer  =  15
                                 PVC Utilization Report Timer  =  500
               PDU Transfer Configuration For Flush-LL Switch  =  Open
                                BC Congestion Alarm Threshold  =  80
                        BC Congestion Restore Alarm Threshold  =  60
                           Reassignment TBF for Different Trx  =  Allow
                                   Allow Clear BitRate In TBF  =  Allow
                                 Support High Multislot Class  =  Not Support
                             Support USF Granularity 4 Switch  =  Support
                                 Support Frequency Hop Switch  =  Support
                                                  Support EDA  =  Not Support
Allow Resource Reassignment While Block Non Ctrl PDCH Channel  =  Allow
                                          Allow EDA Multiplex  =  Not Allow
                                     NC2 Load Reselect Switch  =  Not Support
                                 NC2 Load Broadcast Period(s)  =  4
                                                    Aqm MINth  =  256
                                                    Aqm TarTh  =  384
                                                    Aqm MaxTh  =  1024
                                                   Aqm Switch  =  Close
                                                    Aqm Ninit  =  20
                                              Aqm NLowerBound  =  10
                                                 Aqm NUpBound  =  20
                                                        Aqm M  =  20
                  Channel Distribution Upper Threshold on DSP  =  20
(Number of results = 1)


---    END

Output Description

For details, see the parameter description of the SET PSSOFTPARA command.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.