Modify BTS Alarm Attributes(MOD BTSALM)

Function

A configuration command that modifies the alarm parameters of the BTS. In this command, the following parameters uniquely identify the BTS:

BTS Index or BTS Name

Note

1. The parameters of the BTS3006C and BTS3002E that can be changed include Alarm Shield Flag 1 through Alarm Shield Flag 5, Extended Switch of Alarm, and Alarm Voltage Definition 1 through Alarm Voltage Definition 5.

2. The parameters of the BTS30, BTS312, BTS3002C, BTS3012, BTS3012AE, BTS3012II, DBS3900 GSM, BTS3900 GSM, BTS3900A GSM, DBS3036, BTS3036, BTS3036A or BTS3900E GSM that can be changed include Alarm Shield Flag 1 through Alarm Shield Flag 3, Extended Switch of Alarm, and Alarm Voltage Definition 1 through Alarm Voltage Definition 3.

3. The parameters of the other BTSs that can be changed include Alarm Shield Flag 1 through Alarm Shield Flag 3.

Parameters

ID Name Description
IDXTYPE Index Type

Meaning:Index Type

Value range:BYNAME(By Name),BYIDX(By Index)

Explanation:Index type.

Default value:None

BTSIDX BTS Index

Meaning:BTS Index

Value range:0~2047

Explanation:This parameter specifies the index number of a BTS. Each BTS is numbered uniquely in a BSC.

Default value:None

BTSNAME BTS Name

Meaning:BTS Name

Value range:1-32 characters

Explanation:This parameter specifies the name of a BTS. The name of each BTS is unique in a BSC. Excluding the invalid characters ';',',','"','''','=','\','%%','+++','&','#'.

Default value:None

BTSTYPE BTS Type

Meaning:BTS Type

Value range:BTS22C,BTS20,BTS30,BTS312,BTS3001C,BTS3001CP,BTS3002C,BTS3012A,BTS3006A,BTS3012,BTS3006C,BTS3002E,BTS3012AE,BTS3012_II,DBS3900_GSM,BTS3900_GSM,BTS3900A_GSM,DBS3036,BTS3036,BTS3036A,BTS3900B_GSM,BTS3900E_GSM

Explanation:Type of a BTS,this parameter defined the bts' type.

Default value:None

ALMFLAG1 Alarm Shield Flag 1

Meaning:Alarm Shield Flag 1

Value range:0~255

Explanation:Each bit in the clock parameters indicates whether a Boolean alarm is shielded.1 indicates the Boolean alarm is not shielded and 0 indicates the Boolean alarm is shielded.

Default value:None

ALMFLAG2 Alarm Shield Flag 2

Meaning:Alarm Shield Flag 2

Value range:0~255

Explanation:Each bit in the clock parameters indicates whether a Boolean alarm is shielded.1 indicates the Boolean alarm is not shielded and 0 indicates the Boolean alarm is shielded.

Default value:None

ALMFLAG3 Alarm Shield Flag 3

Meaning:Alarm Shield Flag 3

Value range:0~255

Explanation:Each bit in the clock parameters indicates whether a Boolean alarm is shielded.1 indicates the Boolean alarm is not shielded and 0 indicates the Boolean alarm is shielded.

Default value:None

ALMFLAG4 Alarm Shield Flag 4

Meaning:Alarm Shield Flag 4

Value range:0~255

Explanation:Each bit in the clock parameters indicates whether a Boolean alarm is shielded.1 indicates that the Boolean alarm is unshielded and 0 indicates that the Boolean alarm is shielded.

Default value:None

ALMFLAG5 Alarm Shield Flag 5

Meaning:Alarm Shield Flag 5

Value range:0~255

Explanation:Each bit in the clock parameters indicates whether a Boolean alarm is shielded.1 indicates that the Boolean alarm is unshielded and 0 indicates that the Boolean alarm is shielded.

Default value:None

EXTFLAG Extended Switch of Input Alarm

Meaning:Extended Switch of Input Alarm

Value range:NO(NO),YES(YES)

Explanation:This parameter specifies whether the extended alarm input function for the cabinet top is enabled.

Default value:None

EXTFLAG1 Extended Switch of Alarm

Meaning:Extended Switch of Alarm

Value range:NO(NO),YES(YES)

Explanation:This parameter specifies whether the extended alarm input function for the cabinet top is enabled.

Default value:None

AVD1 Alarm Voltage Definition 1

Meaning:Alarm Voltage Definition 1

Value range:0~255

Explanation:Each bit in the alarm voltage definition field indicates whether a Boolean alarm is triggered in high level or in low level.1 indicates that the alarm is triggered in high level and 0 indicates that the alarm is triggered in low level.

Default value:None

AVD2 Alarm Voltage Definition 2

Meaning:Alarm Voltage Definition 2

Value range:0~255

Explanation:Each bit in the alarm voltage definition field indicates whether a Boolean alarm is triggered in high level or in low level.1 indicates that the alarm is triggered in high level and 0 indicates that the alarm is triggered in low level.

Default value:None

AVD3 Alarm Voltage Definition 3

Meaning:Alarm Voltage Definition 3

Value range:0~255

Explanation:Each bit in the alarm voltage definition field indicates whether a Boolean alarm is triggered in high level or in low level.1 indicates that the alarm is triggered in high level and 0 indicates that the alarm is triggered in low level.

Default value:None

AVD4 Alarm Voltage Definition 4

Meaning:Alarm Voltage Definition 4

Value range:0~255

Explanation:Each bit in the alarm voltage definition field indicates whether a Boolean alarm is triggered in high level or in low level.1 indicates that the alarm is triggered in high level and 0 indicates that the alarm is triggered in low level.

Default value:None

AVD5 Alarm Voltage Definition 5

Meaning:Alarm Voltage Definition 5

Value range:0~255

Explanation:Each bit in the alarm voltage definition field indicates whether a Boolean alarm is triggered in high level or in low level.1 indicates that the alarm is triggered in high level and 0 indicates that the alarm is triggered in low level.

Default value:None

AVD6 Alarm Voltage Definition-1

Meaning:Alarm Voltage Definition-1

Value range:0~255

Explanation:Each bit in the alarm voltage definition field indicates whether a Boolean alarm is triggered in high level or in low level.1 indicates that the alarm is triggered in high level and 0 indicates that the alarm is triggered in low level.

Default value:None

AVD7 Alarm Voltage Definition-2

Meaning:Alarm Voltage Definition-2

Value range:0~255

Explanation:Each bit in the alarm voltage definition field indicates whether a Boolean alarm is triggered in high level or in low level.1 indicates that the alarm is triggered in high level and 0 indicates that the alarm is triggered in low level.

Default value:None

AVD8 Alarm Voltage Definition-3

Meaning:Alarm Voltage Definition-3

Value range:0~255

Explanation:Each bit in the alarm voltage definition field indicates whether a Boolean alarm is triggered in high level or in low level.1 indicates that the alarm is triggered in high level and 0 indicates that the alarm is triggered in low level.

Default value:None

Example

Suppose the serving BTS is the BTS30, modify the alarm parameters of the BTS (Index Type = BYIDX(By Index); BTS Index = 0; BTS Type = BTS30; Alarm Shield Flag 1 = 1; Alarm Shield Flag 2 = 2; Alarm Shield Flag 3 = 3; Extended Switch of Alarm = YES(YES); Alarm Voltage Definition 1 = 4; Alarm Voltage Definition 2 = 5; Alarm Voltage Definition 3 = 6):
MOD BTSALM: IDXTYPE=BYIDX, BTSIDX=0, BTSTYPE=BTS30, AlmFlag1=1, AlmFlag2=2, AlmFlag3=3, EXTFlag1=YES, AVD6=4, AVD7=5, AVD8=6;
Related reference
Add BTS(ADD BTS)