1. This command applies to the BTS3006A only.
2. The BTS3006A must be configured with the OSSU, which is connected to the auxiliary equipment. Currently, the auxiliary equipment refers to only the heat exchanger.
3. Running this command resets the auxiliary equipment. Use this command with caution.
ID | Name | Description |
---|---|---|
SITEIDXTYPE | Site Index Type | Meaning: how to specify a BTS Value range: BYNAME(By Name), BYIDX(By Index) Explanation: This parameter determines whether to specify a BTS by name or by index. Default value: None |
SITEIDX | Site Index | Meaning: BTS index Value range: 0-2047 Explanation: 1. This parameter specifies the index number of the BTS. Each BTS is numbered uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYIDX(By Index). Default value: None |
SITENAME | Site Name | Meaning: BTS name Value range: 1-32 characters Explanation: 1. This parameter specifies the name of the BTS. Each BTS is named uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYNAME(By Name). Default value: None |
SRN | Subrack No | Meaning: subrack number Value range: 0-53 Explanation: This parameter specifies the number of the subrack where the board connected to the auxiliary equipment is located. The subrack number is unique in a BTS. Default value: None |
SN | Slot No | Meaning: slot number Value range: 0-23 Explanation: This parameter specifies the number of the slot that holds the board connected to the auxiliary equipment of the BTS. Default value: None |
EQPTYPE | Equipment Type | Meaning: type of the auxiliary equipment Value range: HEATEXCHANGER Explanation: This parameter specifies the type of the auxiliary equipment. Currently, only the heat exchanger is supported. Default value: None |