1. The MML communicates properly with the BSC.
2. The BSC communicates properly with the BTS.
3. Resetting the BTS EAC may affect the environment monitoring of the BTS, so use this command with caution.
4. You can view whether the DEMU is configured on the BTS through the "DSP DEMUCFGINFO" command.
ID | Name | Description |
---|---|---|
IDXTYPE | Index type | Meaning: how to specify a BTS Value range: BYNAME(By Name), BYIDX(By Index) Explanation: This parameter determines whether to specify a BTS by its name or index. Default value: None |
BTSIDX | BTS Index | Meaning: BTS index Value range: 0-2047 Explanation: 1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYIDX(By Index). Default value: None |
BTSNAME | BTS Name | Meaning: BTS name Value range: 1-32 characters Explanation: 1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYNAME(By Name). Default value: None |
ISSPTDEMUS | Demu configure information | Meaning: This parameter specifies whether the DEMU is configured. Value range: YES(Configure), NO(Not Configure) Explanation: 1. A key field that identifies the EAC reset and indicates whether the DEMU is configured in the BTS where the EAC is located. 2. YES(Configure) indicates that the DEMU is configured and NO(Not Configure) indicates that the DEMU is not configured. Default value: None |
SRN | Subrack No. | Meaning: subrack number of the DEMU Value range: 0-53 Explanation: 1. This parameter specifies the number of the subrack where a BTS board is located. The subrack number is unique in a site. 2. This parameter specifies the subrack number of the DEMU when the EAC is reset. 3. This parameter is mandatory when the YES(Support) option is selected. Default value: None |
SN | Slot No. | Meaning: slot number of the DEMU Value range: 0-23 Explanation: 1. This parameter specifies the number of the slot in which a BTS board is located. 2. This parameter specifies the slot number of the DEMU when the EAC is reset. 3. This parameter is mandatory when the YES(Support) option is selected. Default value: None |