Reset RET Antenna Tilt Angle(RST RETANTTILT)

Function

An OM command that calibrates the starting point of the motor of the RET antenna.

Note

1. The MML client must run properly.

2. The BSC must communicate properly with the BTS.

3. The BTS must be configured with the board that controls the RET antenna and connected with the RET antenna.

4. The running of this command calibrates the starting point of the RET antenna motor. Run this command when the RET antenna is started for the first time or when the alarm related to the RET antenna is reported.

Parameters

ID Name Description
IDXTYPE Index Type

Meaning: how to specify a BTS

Value range: BYNAME(By Name), BYIDX(By Index)

Explanation: This parameter determines whether to specify a BTS by its name or index.

Default value: None

BTSIDX BTS Index

Meaning: BTS index

Value range: 0-2047

Explanation:

1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYIDX(By Index).

Default value: None

BTSNAME BTS Name

Meaning: BTS name

Value range: 1-32 characters

Explanation:

1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYNAME(By Name).

Default value: None

SRN Subrack No.

Meaning: subrack number

Value range: 0-53

Explanation: This parameter specifies the number of the subrack in which the board that controls the RET antenna is located. The subrack number is unique in a BTS.

Default value: None

SN Slot No.

Meaning: slot number

Value range: 0-23

Explanation: This parameter specifies the number of the slot that holds the board that controls the RET antenna.

Default value: None

ANTNO Antenna No

Meaning: antenna number

Value range: 0-35

Explanation: This parameter specifies the number of a RET antenna.

Default value: None

Example

Reset the tilt angle of RET antenna (Index Type = BYIDX(By Index); BTS Index = 0; Subrack No. = 0; Slot No. = 3; Antenna No = 0):
RST RETANTTILT: IDXTYPE=BYIDX, BTSIDX=0, SRN=0, SN=3, ANTNO=0;
The result is as follows:
+++    HUAWEI        2008-02-20 17:02:16
O&M    #11
%%RST RETANTTILT: IDXTYPE=BYIDX, BTSIDX=0, SRN=0, SN=3, ANTNO=0;%%
RETCODE = 0  Execution succeeded


Subsequent reports to be output

---    END

+++    HUAWEI        2008-02-20 17:02:22
O&M    #11
%%RST RETANTTILT: IDXTYPE=BYIDX, BTSIDX=0, SRN=0, SN=3, ANTNO=0;%%
RETCODE = 0  Execution succeeded

Restore the RET antenna tilt angle
----------------
Progress  =  16%
(Number of results = 1)


Subsequent reports to be output

---    END

......

+++    HUAWEI        2008-02-21 18:02:00
O&M    #3791
%%RST RETANTTILT: IDXTYPE=BYIDX, BTSIDX=0, SRN=0, SN=3, ANTNO=0;%%
RETCODE = 0  Execution succeeded

Restore the RET antenna tilt angle
----------------
Progress  =  100%
(Number of results = 1)


13 reports in total