Set Forced Tuning of Cavity Frequency(SET BTSFRCINCH)

Function

An CFG command used to force fine tuning of cavity frequency.

Note

1. The MML client communicates properly with the BSC.

2. The BSC communicates properly with the BTS.

3. The BTS is configured with the DFCU.

Parameters

ID Name Description
IDXTYPE Index Type

Meaning: how to specify a BTS

Value range: BYNAME(By Name), BYIDX(By Index)

Explanation: This parameter determines whether to specify a BTS by its name or index.

Default value: None

BTSIDX BTS Index

Meaning: BTS index

Value range: 0-2047

Explanation:

1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYIDX(By Index).

Default value: None

BTSNAME BTS Name

Meaning: BTS name

Value range: 1-32 characters

Explanation:

1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYNAME(By Name).

Default value: None

SRN Subrack No.

Meaning: subrack number

Value range: 0-53

Explanation: This parameter specifies the number of the subrack where a BTS board is located. The subrack number is unique in a site.

Default value: None

SN Slot No.

Meaning: slot number

Value range: 0-23

Explanation: This parameter specifies the number of the slot in which a BTS board is located.

Default value: None

Example

1. Set forced tuning of cavity frequency for a DFCU (Index Type = BYIDX(By Index); BTS Index = 0; Subrack No. = 0; Slot No. = 4):
SET BTSFRCINCH:IDXTYPE=BYIDX,BTSIDX=0,SRN=0,SN=4;

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.