Modify STM1 Sub-board Attributes(SET OPTSUBBRD)

Function

A configuration command that sets the parameters of the sub-board of an optical interface board. In this command, the following parameters uniquely identify an optical interface board:

Subrack No.

Slot No.

To modify sub-board attributes of all the optical interface boards in a specified subrack, set Subrack No..

To modify sub-board attributes of a specified optical interface board, set Subrack No. and Slot No..

Note

2. When the optical interface boards work in active/standby mode, if the sub-board attributes of one board are modified, those of the other board are modified automatically.

2. The value of B2 Signal Disabled Threshold must be larger than or equal to that of B2 Signal Degraded Threshold. The value of B3 Signal Disabled Threshold must be larger than or equal to that of B3 Signal Degraded Threshold.

Parameters

ID Name Description
SRN Subrack No.

Meaning:Subrack No.

Value range:0~11

Explanation:None.

Default value:None

SN Slot No.

Meaning:Slot No.

Value range:0~27

Explanation:None.

Default value:None

LINK_NUM_MODE Tributary Numbering

Meaning:Tributary Numbering

Value range:LUCENT_MODE(Lucent Mode),HUAWEI_MODE(Huawei Mode),ALCATEL_MODE(Alcatel Mode)

Explanation:This parameter indicates the sequence of tributaries in an SDH frame.

Default value:None

J0_LENGTH J0 Mode

Meaning:J0 Mode

Value range:1_Byte(1 Byte),16_Byte(16 Byte)

Explanation:This parameter indicates the display mode of TX J0 Byte and Expect RX J0 Byte.

When this parameter is set to Character String, some characters may not be entered. The characters can be entered in hexadecimal mode. The characters that cannot be entered from the keyboard can also be entered in Hexadecimal mode.

The Character String mode can be switched to the Hexadecimal mode, however, the Hexadecimal mode may not be switched to the Character String mode. The Hexadecimal mode can be switched over to the Character String mode only when all the characters can be entered from the keyboard..

Default value:None

J0BYTE_FORMAT J0 Display Mode

Meaning:J0 Display Mode

Value range:Hexadecimal(Hexadecimal),Character_String(Character String)

Explanation:J0 Byte Format.

Default value:None

TX_J0_INFO TX J0 Byte

Meaning:TX J0 Byte

Value range:1-30 characters

Explanation:This byte repeatedly sends segment access point identifiers so that the receiving end can check that it is connected with the specified transmitting end.

Default value:None

EXPECT_RX_J0_INFO Expect RX J0 Byte

Meaning:Expect RX J0 Byte

Value range:1-30 characters

Explanation:This byte repeatedly sends segment access point identifiers so that the receiving end can check that it is connected with the specified transmitting end.

Default value:None

J1_LENGTH J1 Mode

Meaning:J1 Mode

Value range:1_Byte(1 Byte),16_Byte(16 Byte),64_Byte(64 Byte)

Explanation:This parameter indicates the display mode of TX J1 Byte and Expect RX J1 Byte.

When this parameter is set to Character String, some characters may not be entered. The characters can be entered in hexadecimal mode. The characters that cannot be entered from the keyboard can also be input under the Hexadecimal mode.

The Character String mode can be switched to the Hexadecimal mode, however, the Hexadecimal mode may not be switched to the Character String mode. The Hexadecimal mode can be switched over to the Character String mode only when all the characters can be typed into on the keyboard.

Default value:None

J1BYTE_FORMAT J1 Display Mode

Meaning:J1 Display Mode

Value range:Hexadecimal(Hexadecimal),Character_String(Character String)

Explanation:J1 Byte Format.

Default value:None

OPTSTANDARD Optical Interface Standard

Meaning:Optical Interface Standard

Value range:SDH(SDH),SONET(SONET)

Explanation:Optical Interface Standard.

Default value:None

TX_J1_INFO TX J1 Byte

Meaning:TX J1 Byte

Value range:1-128 characters

Explanation:J1 repeatedly sends segment access point identifiers of the higher order path so that the receiving end of the path can check that it is connected with the specified transmitting end.

Default value:None

EXPECT_RX_J1_INFO Expect RX J1 Byte

Meaning:Expect RX J1 Byte

Value range:1-128 characters

Explanation:J1 repeatedly sends segment access point identifiers of the higher order path so that the receiving end of the path can check that it is connected with the specified transmitting end.

Default value:None

TX_J1_INFO_PATH1 High Order Path 1 TX J1 Byte

Meaning:High Order Path 1 TX J1 Byte

Value range:1-128 characters

Explanation:J1 repeatedly sends segment access point identifiers of the higher order path so that the receiving end of the path can check that it is connected with the specified transmitting end.

Default value:None

EXPECT_RX_J1_INFO_PATH1 High Order Path 1 Expect RX J1 Byte

Meaning:High Order Path 1 Expect RX J1 Byte

Value range:1-128 characters

Explanation:J1 repeatedly sends segment access point identifiers of the higher order path so that the receiving end of the path can check that it is connected with the specified transmitting end.

Default value:None

TX_J1_INFO_PATH2 High Order Path 2 TX J1 Byte

Meaning:High Order Path 2 TX J1 Byte

Value range:1-128 characters

Explanation:J1 repeatedly sends segment access point identifiers of the higher order path so that the receiving end of the path can check that it is connected with the specified transmitting end.

Default value:None

EXPECT_RX_J1_INFO_PATH2 High Order Path 2 Expect RX J1 Byte

Meaning:High Order Path 2 Expect RX J1 Byte

Value range:1-128 characters

Explanation:J1 repeatedly sends segment access point identifiers of the higher order path so that the receiving end of the path can check that it is connected with the specified transmitting end.

Default value:None

TX_J1_INFO_PATH3 High Order Path 3 TX J1 Byte

Meaning:High Order Path 3 TX J1 Byte

Value range:1-128 characters

Explanation:J1 repeatedly sends segment access point identifiers of the higher order path so that the receiving end of the path can check that it is connected with the specified transmitting end.

Default value:None

EXPECT_RX_J1_INFO_PATH3 High Order Path 3 Expect RX J1 Byte

Meaning:High Order Path 3 Expect RX J1 Byte

Value range:1-128 characters

Explanation:J1 repeatedly sends segment access point identifiers of the higher order path so that the receiving end of the path can check that it is connected with the specified transmitting end.

Default value:None

S1_TYPE Set TX S1 Byte

Meaning:Set TX S1 Byte

Value range:NO(No),YES(Yes)

Explanation:This parameter indicates whether the S1 byte is enabled.

Default value:None

S1_BYTE_VALUE TX S1 Byte

Meaning:TX S1 Byte

Value range:0~15

Explanation:This parameter indicates the synchronization status byte.

Default value:None

B1B2_SFTHRD B2 Signal Disabled Threshold

Meaning:B2 Signal Disabled Threshold

Value range:O1E3_R1E4(OCCUR:1E-3, RECOVERY:1E-4),O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5),O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6),O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7),O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8),O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9),O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10)

Explanation:This parameter specifies the generation threshold and the recovery threshold of the B1B2 signal failure threshold in SDH frames at the optical port.

B1B2 SF threshold value range:

If the RSF alarm trigger source in the optical port is based on B1, the value range is 1-6;

If the RSF alarm trigger source in the optical port is based on B2, the value range is 0-6;

Explanation:

0-generation threshold: 1E-3; recovery threshold: 1E-4;

1-generation threshold: 1E-4; recovery threshold: 1E-5;

2-generation threshold: 1E-5; recovery threshold: 1E-6;

3-generation threshold: 1E-6; recovery threshold: 1E-7;

4-generation threshold: 1E-7; recovery threshold: 1E-8;

5-generation threshold: 1E-8; recovery threshold: 1E-9;

6-generation threshold: 1E-9; recovery threshold: 1E-10;.

Default value:None

B1B2_SDTHRD B2 Signal Degraded Threshold

Meaning:B2 Signal Degraded Threshold

Value range:O1E3_R1E4(OCCUR:1E-3, RECOVERY:1E-4),O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5),O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6),O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7),O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8),O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9),O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10)

Explanation:This parameter specifies the generation threshold and the recovery threshold of the B1B2 signal degradation threshold in SDH frames at the optical port.

B1B2 SD threshold value range:

If the RSD alarm trigger source in the optical port is based on B1, the value range is 1-6;

If the RSD alarm trigger source in the optical port is based on B2, the value range is 0-6;

Explanation:

0-generation threshold: 1E-3; recovery threshold: 1E-4;

1-generation threshold: 1E-4; recovery threshold: 1E-5;

2-generation threshold: 1E-5; recovery threshold: 1E-6;

3-generation threshold: 1E-6; recovery threshold: 1E-7;

4-generation threshold: 1E-7; recovery threshold: 1E-8;

5-generation threshold: 1E-8; recovery threshold: 1E-9;

6-generation threshold: 1E-9; recovery threshold: 1E-10;.

Default value:None

B3_SFTHRD B3 Signal Disabled Threshold

Meaning:B3 Signal Disabled Threshold

Value range:O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5),O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6),O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7),O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8),O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9),O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10)

Explanation:This parameter specifies the generation threshold and the recovery threshold of the B3 signal failure threshold in SDH frames at the optical port.

Default value:None

B3_SDTHRD B3 Signal Degraded Threshold

Meaning:B3 Signal Degraded Threshold

Value range:O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5),O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6),O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7),O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8),O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9),O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10)

Explanation:This parameter specifies the generation threshold and the recovery threshold of the B3 signal degradation threshold in SDH frames at the optical port.

Default value:None

Example

1. Set the attributes of a sub-board of the optical interface board (Subrack No. = 0; Slot No. = 14; Tributary numbering = HUAWEI_MODE(Huawei Mode)):
SET OPTSUBBRD: SRN=0, SN=14, LINK_NUM_MODE=HUAWEI_MODE;