Stop Test Battery of BTS(STP BTSBATTTST)

Function

An OM command that stops the BTS battery test.

Note

1. The BSC must communicate properly with the BTS.

2. The BTS must be configured with the battery.

Parameters

ID Name Description
IDXTYPE Index Type

Meaning: how to specify a BTS

Value range: BYNAME(By Name), BYIDX(By Index)

Explanation: This parameter determines whether to specify a BTS by its name or index.

Default value: None

STIDX Site Index

Meaning: BTS index

Value range: 0-2047

Explanation:

1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYIDX(By Index).

Default value: None

STNAME Site Name

Meaning: BTS name

Value range: 1-32 characters

Explanation:

1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYNAME(By Name).

Default value: None

SRN Subrack No.

Meaning: subrack number

Value range: 0-53

Explanation: This parameter specifies the number of the subrack in which the BTS power module is located. The subrack number is unique in a BTS.

Default value: None

SN Slot No.

Meaning: slot number

Value range: 0-23

Explanation: This parameter specifies the number of the slot in which the BTS power module is located.

Default value: None

Example

Stop the test on the battery (Index Type = BYIDX(By Index); Site Index = 0; Subrack No. = 0; Slot No. = 15):
STP BTSBATTTST: IDXTYPE=BYIDX, STIDX=0, SRN=0, SN=15;

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.