Stop BTS Temper Minitor(STP BTSRACKTEMPMON)

Function

An OM command that stops the monitoring on the BTS ambient temperature.

Note

The BSC must communicate properly with the BTS.

Parameters

ID Name Description
SITEIDXTYPE Site Index Type

Meaning: how to specify a BTS

Value range: BYNAME(By Name), BYIDX(By Index)

Explanation: This parameter determines whether to specify a BTS by its name or index.

Default value: None

SITEIDX Site Index

Meaning: BTS index

Value range: 0-2047

Explanation:

1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYIDX(By Index).

Default value: None

SITENAME Site Name

Meaning: BTS name

Value range: 1-32 characters

Explanation:

1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYNAME(By Name).

Default value: None

Example

Stop the monitoring of the BTS ambient temperature (Site Index Type = BYIDX(By Index); Site Index = 0):
STP BTSRACKTEMPMON: SITEIDXTYPE=BYIDX, SITEIDX=0;

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.