Stop Trx Performance Test(STP TRXPERFTST)

Function

An OM command that stops the TRX performance test.

Note

1. The BSC must communicate properly with the BTS.

2. The TRX performance test must be initiated.

Parameters

ID Name Description
IDXTYPE Index Type

Meaning: how to specify a BTS

Value range: BYNAME(By Name), BYIDX(By Index)

Explanation: This parameter determines whether to specify a BTS by its name or index.

Default value: None

BTSIDX BTS Index

Meaning: BTS index

Value range: 0-2047

Explanation:

1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYIDX(By Index).

Default value: None

BTSNAME BTS Name

Meaning: BTS name

Value range: 1-32 characters

Explanation:

1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC.

2. This parameter is mandatory if Index Type is set to BYNAME(By Name).

Default value: None

Example

Stop the TRX performance test (Index Type = BYIDX(By Index); BTS Index = 0):
STP TRXPERFTST: IDXTYPE=BYIDX, BTSIDX=0;