1. The BSC must communicate properly with the BTS.
2. The BTS must be configured with the battery.
3. To protect the battery, conduct the test at an appropriate interval. The default interval is 14 days.
4. The duration of the simple test depends on the factory settings of the battery. Generally, the duration is 30 minutes or 1 hour.
ID | Name | Description |
---|---|---|
IDXTYPE | Index Type | Meaning: how to specify a BTS Value range: BYNAME(By Name), BYIDX(By Index) Explanation: This parameter determines whether to specify a BTS by name or by index. Default value: None |
STIDX | Site Index | Meaning: BTS index Value range: 0-2047 Explanation: 1. This parameter specifies the number of the target BTS. Each BTS is numbered uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYIDX(By Index). Default value: None |
STNAME | Site Name | Meaning: BTS name Value range: 1-32 characters Explanation: 1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYNAME(By Name). Default value: None |
SRN | Subrack No. | Meaning: subrack number Value range: 0-53 Explanation: This parameter specifies the number of the subrack in which the BTS power module is located. The subrack number is unique in a BTS. Default value: None |
SN | Slot No. | Meaning: slot number Value range: 0-23 Explanation: This parameter specifies the number of the slot that holds the BTS power module. Default value: None |
TSTTYPE | Test Type | Meaning: test mode Value range: SIMPLETEST(Simple Test), MANUALTEST(Manual Test) Explanation: This parameter specifies the mode of testing the battery. This parameter is mandatory. Default value: None |