Start DSP TC Loop(STR DSPTCLOP)

Function

An OM command that starts the loopback test on the DSP channel.

Note

1. The DPU must work normally.

2. The subrack number and slot number to be entered must be the numbers of the subrack and slot where the DPU is located.

3. During the loopback test on a DSP channel, services on this channel are disrupted. Use this command with caution.

Parameters

ID Name Description
SRN Subrack No.

Meaning: subrack number

Value range: 0-11

Explanation: This parameter specifies the number of the subrack where the GDPUC or GDPUX is located.

Default value: None

SN Slot No.

Meaning: slot number

Value range: 0-27

Explanation: This parameter specifies the number of the slot that holds the GDPUC or GDPUX.

Default value: None

DSPN DSP No.

Meaning: number of the DSP

Value range: 0-21

Explanation: This parameter specifies the number of the DSP.

Default value: None

STRCHN Start channel

Meaning: number of the start channel

Value range: 0-69

Explanation: This parameter specifies the number of the start channel.

Default value: None

ENDCHN End channel

Meaning: number of the end channel

Value range: 0-69

Explanation: The number of the end channel cannot be smaller than the number of the start channel.

Default value: None

LOPMOD Loop mode

Meaning: loopback mode

Value range: AITF, ABISITF

Explanation: The value AITF indicates that the loopback is performed on the A interface; the value ABISITF indicates that the loopback is performed on the Abis interface.

Default value: None

Example

Start the loopback test on a DSP channel (Subrack No. = 1; Slot No. = 9; DSP No. = 0; Start channel = 0; End channel = 0; Loop mode = AITF):
STR DSPTCLOP: SRN=1, SN=9, DSPN=0, STRCHN=0, ENDCHN=0, LOPMOD=AITF;

Output Description

None.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.