1. The BSC must communicate properly with the BTS.
2. The running of this command leads to the resetting of the BTS, which disrupts the services. Use this command with caution.
ID | Name | Description |
---|---|---|
IDXTYPE | Index Type | Meaning: how to specify a BTS Value range: BYNAME(By Name), BYIDX(By Index) Explanation: This parameter determines whether to specify a BTS by its name or index. Default value: None |
BTSIDX | BTS Index | Meaning: BTS index Value range: 0-2047 Explanation: 1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYIDX(By Index). Default value: None |
BTSNAME | BTS Name | Meaning: BTS name Value range: 1-32 characters Explanation: 1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYNAME(By Name). Default value: None |
SLPTYPE | Self loop type | Meaning: mode of self loop Value range: E1SELFLOOP, IASUSELFLOOP Explanation: Only the BTS3002C, BTS3006C, and BTS3002E support the IASUSELFLOOP mode. Default value: None |
E1SLCTTMU | TMU type | Meaning: TMU type in E1SELFLOOP mode Value range: ACTIVE(ACTIVE TMU/MMU/IOMU/DOMU), ACTIVESTANDBY(ACTIVE/STANDBY TMU), SLAVE1(SLAVE TMU1/DOMU1), SLAVE2(SLAVE TMU2/DOMU2) Explanation: 1. For the BTS3002C, BTS3001C, and BTS3001CP, set this parameter to ACTIVE(ACTIVE TMU/MMU/IOMU/DOMU). 2. For the BTS3006C and BTS3002E, do not set this parameter to ACTIVESTANDBY(ACTIVE/STANDBY TMU). Default value: None |
LPBKMODE | Loop back mode | Meaning: loopback mode Value range: E1(E1 LOOP BACK), TIMESLOT(TIMESLOT LOOP BACK) Explanation: This parameter specifies the loopback mode. Default value: None |
E1PORT | Port | Meaning: E1 port number Value range: 0-7 Explanation: For the BTS3012, BTS3012AE, and BTS3012 II, the value range is from 0 to 7; For other BTSs, the value range is from 0 to 3. Default value: None |
E1DURAT | Duration | Meaning: duration in E1 loop back mode Value range: 1-60 Explanation: This parameter specifies the duration in E1 loopback mode. The parameter is expressed in minutes. Default value: None |
TSDURAT | Duration * 10 minutes | Meaning: duration in timeslot loopback mode (*10 minutes) Value range: 1-144 Explanation: This parameter specifies the duration in timeslot loopback mode. Default value: None |
TSTTIMESLOT | Test timeslot | Meaning: number of the timeslot to be tested Value range: 0-31 Explanation: This parameter specifies the number of timeslots to be tested. Default value: None |
IASUSLCTTMU | TMU type | Meaning: TMU type in IASUSELFLOOP mode Value range: MAINDOMU, SLAVEDOMU1, SLAVEDOMU2 Explanation: The BTS3002C supports only the MAINDOMU type. Default value: None |
IASUPORT | Port | Meaning: type of ports in IASUSELFLOOP mode Value range: E1PORT0, E1PORT1, E1PORT2, E1PORT3, OPTICALPORT0, OPTICALPORT1 Explanation: The BTS3002C does not support the E1PORT3. Default value: None |
IASUDURAT | Duration | Meaning: duration in IASUSELFLOOP mode Value range: 1-60 Explanation: This parameter specifies the duration in IASUSELFLOOP mode. The parameter is expressed in minutes. Default value: None |
Start the BTS transmission performance test (Index Type = BYIDX(By Index); BTS Index = 0; Self loop type = E1SELFLOOP; TMU type = ACTIVE(ACTIVE TMU/MMU/IOMU/DOMU); Loop back mode = E1(E1 LOOP BACK); Port = 0; Duration = 1): STR TRANSPERFTST: IDXTYPE=BYIDX, BTSIDX=0, SLPTYPE=E1SELFLOOP, E1SLCTTMU=ACTIVE, LPBKMODE=E1, E1PORT=0, E1DURAT=1;