1. The BSC must communicate properly with the BTS.
2. The running of this command leads to the resetting of the BTS, which disrupts the services. Use this command with caution.
| ID | Name | Description |
|---|---|---|
| IDXTYPE | Index Type | Meaning: how to specify a BTS Value range: BYNAME(By Name), BYIDX(By Index) Explanation: This parameter determines whether to specify a BTS by its name or index. Default value: None |
| BTSIDX | BTS Index | Meaning: BTS index Value range: 0-2047 Explanation: 1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYIDX(By Index). Default value: None |
| BTSNAME | BTS Name | Meaning: BTS name Value range: 1-32 characters Explanation: 1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYNAME(By Name). Default value: None |
| SLPTYPE | Self loop type | Meaning: mode of self loop Value range: E1SELFLOOP, IASUSELFLOOP Explanation: Only the BTS3002C, BTS3006C, and BTS3002E support the IASUSELFLOOP mode. Default value: None |
| E1SLCTTMU | TMU type | Meaning: TMU type in E1SELFLOOP mode Value range: ACTIVE(ACTIVE TMU/MMU/IOMU/DOMU), ACTIVESTANDBY(ACTIVE/STANDBY TMU), SLAVE1(SLAVE TMU1/DOMU1), SLAVE2(SLAVE TMU2/DOMU2) Explanation: 1. For the BTS3002C, BTS3001C, and BTS3001CP, set this parameter to ACTIVE(ACTIVE TMU/MMU/IOMU/DOMU). 2. For the BTS3006C and BTS3002E, do not set this parameter to ACTIVESTANDBY(ACTIVE/STANDBY TMU). Default value: None |
| LPBKMODE | Loop back mode | Meaning: loopback mode Value range: E1(E1 LOOP BACK), TIMESLOT(TIMESLOT LOOP BACK) Explanation: This parameter specifies the loopback mode. Default value: None |
| E1PORT | Port | Meaning: E1 port number Value range: 0-7 Explanation: For the BTS3012, BTS3012AE, and BTS3012 II, the value range is from 0 to 7; For other BTSs, the value range is from 0 to 3. Default value: None |
| E1DURAT | Duration | Meaning: duration in E1 loop back mode Value range: 1-60 Explanation: This parameter specifies the duration in E1 loopback mode. The parameter is expressed in minutes. Default value: None |
| TSDURAT | Duration * 10 minutes | Meaning: duration in timeslot loopback mode (*10 minutes) Value range: 1-144 Explanation: This parameter specifies the duration in timeslot loopback mode. Default value: None |
| TSTTIMESLOT | Test timeslot | Meaning: number of the timeslot to be tested Value range: 0-31 Explanation: This parameter specifies the number of timeslots to be tested. Default value: None |
| IASUSLCTTMU | TMU type | Meaning: TMU type in IASUSELFLOOP mode Value range: MAINDOMU, SLAVEDOMU1, SLAVEDOMU2 Explanation: The BTS3002C supports only the MAINDOMU type. Default value: None |
| IASUPORT | Port | Meaning: type of ports in IASUSELFLOOP mode Value range: E1PORT0, E1PORT1, E1PORT2, E1PORT3, OPTICALPORT0, OPTICALPORT1 Explanation: The BTS3002C does not support the E1PORT3. Default value: None |
| IASUDURAT | Duration | Meaning: duration in IASUSELFLOOP mode Value range: 1-60 Explanation: This parameter specifies the duration in IASUSELFLOOP mode. The parameter is expressed in minutes. Default value: None |
Start the BTS transmission performance test (Index Type = BYIDX(By Index); BTS Index = 0; Self loop type = E1SELFLOOP; TMU type = ACTIVE(ACTIVE TMU/MMU/IOMU/DOMU); Loop back mode = E1(E1 LOOP BACK); Port = 0; Duration = 1): STR TRANSPERFTST: IDXTYPE=BYIDX, BTSIDX=0, SLPTYPE=E1SELFLOOP, E1SLCTTMU=ACTIVE, LPBKMODE=E1, E1PORT=0, E1DURAT=1;