Cfg RFU by Slot

Parameter Name

Cfg RFU by Slot

Description

1. This parameter specifies whether to configure the DRFU, MRFU, GRFU, or XRFU by slot or link.

2. When setting the BTS to support the configuration of the RFU by slot, set this parameter to "YES". When setting the BTS not to support the configuration of the RFU by slot, set this parameter to "NO".

3. If this parameter is set to "YES", you must enter the numbers of the subrack and slot where the new board is located.

If you need to specify the CPRI connection relations (SFP port number and cascading level) based on a rule that is different from the cabinet mapping rule specified by the system, the parameters "RXU Chain Head Port No." and "Insert RXU Position" must be specified.

4. If this parameter is set to "NO", you must set "TRX Board No.", "RFU Link No." and "RXU Chain Head Port No.".

GUI Value Range

[No,Yes]

Default Value

No

Unit

None

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

None

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Radio Resources

Caution

None


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.