BTS Paging Lifetime

Parameter Name

BTS Paging Lifetime

Description

Lifetime of a paging message in the queue of the BTS. The setting of this parameter must be consistent with the setting of timer T3113 in the core network; otherwise, the efficiency of paging scheduling over the Um interface is reduced. It is recommended that this parameter be set to a value one to two seconds shorter than timer T3113.The valid parameter value is 255 or a value ranging from 8 to 80. The BTS checks the value. If the value is out of the range, the BTS considers it as default value, 255.

GUI Value Range

[0,255]

Default Value

255

Unit

250ms

Step

-

Modification Rules

None

Configuration Policy

None

Recommended Value

None

Parameter Relationship

None

BSC Feature

None

Parameter Class

Parameters About Transmission

Caution

None


Huawei Proprietary and Confidential