Parameter Name |
Subboard Slot No. |
---|---|
Description |
This parameter specifies the number of a sub-board. |
GUI Value Range |
[0,3] |
Default Value |
None |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
When the GXPUT/GXPUM is configured, two sub-boards are automatically configured. The GSCU must exist before a GXPUT/GXPUM is added because the GSCU is required to perform arbitration. When the GDPUC is configured, two DSP sub-boards are automatically configured in subslots 0 and 1. When the GEIU is configured, one E1/T1 sub-board is automatically configured in subslot 0. When the GOIU is configured, one optical sub-board is automatically configured in subslot 0. |
Recommended Value |
None |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
None |