Parameter Name |
Upper Threshold of Measurement Range of External Analog 2 |
---|---|
Description |
This parameter specifies the upper limit of measurement range of an external analog sensor. When the measurement range of an external analog sensor exceeds the threshold, an alarm is generated if Enable Analog Parameter Alarm Reporting is set to Open. The value of this parameter is a floating-point value set by the user according to actual requirements. |
GUI Value Range |
[-32768.00,32767.00] |
Default Value |
60.00 |
Unit |
None |
Step |
- |
Modification Rules |
None |
Configuration Policy |
The measurement range may be inaccurate if this parameter is set to a too great or too small value. It is recommended that the value range according to the type of the actually used external analog sersor. |
Recommended Value |
60.00 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
The external analog sensor 2 has two types of input: voltage and current. Upper Limit of Measurement Range of External Analog 2 should be greater than or equal to Lower Limit of Measurement Range of External Analog 2. |