Parameter Name |
Lower Limit of Temperature Alarm(℃) |
---|---|
Description |
This parameter indicates the lower limit of the temperature alarm. If the temperature of the cabinet where the environment monitor device is located is lower than this parameter, the Abnormal Temperature alarm is generated. |
GUI Value Range |
[0.00,45.00] |
Default Value |
0.00 |
Unit |
℃ |
Step |
- |
Modification Rules |
None |
Configuration Policy |
If this parameter is set to an overlarge or oversmall value, some alarms may not be reported. Huawei recommends that you retain the default value. |
Recommended Value |
0.00 |
Parameter Relationship |
None |
BSC Feature |
None |
Parameter Class |
Parameters About Equipment |
Caution |
Lower Limit of Temperature Alarm cannot be greater than Upper Limit of Temperature Alarm. |